Troubleshooting (Indicators); Cleaning And Replacing The Air Filter - Sagem FLP 3000-X User Manual

Lcd projector
Table of Contents

Advertisement

TROUBLESHOOTING (INDICATORS)

You can check the status of the projector using the indicators
on the projector's control panel. Refer to the table below
for the cause of problems.
: Lighting
Status

CLEANING AND REPLACING THE AIR FILTER

The air filter must be cleaned about every 300 hours. If dust accumulates too much and becomes difficult to
remove by using vacuum cleaner, please replace the air filter to keep the ventilation of LCD panel module in
good condition. The projector attaches one spare air filter for replacement. If more is required, please contact
the agent for purchasing or consultation.
User can clean or replace the air filter by following the steps below.
1. Power off the projector and disconnect the power cable.
2. Turn the unit bottom up and open the filter cover.
3. Remove the air filter, and use a vacuum cleaner to clean away
the dust, or replace a new one directly.
4. Attach the air filter and install the filter cover.
: Flashing
Cause & Remedy
Standby condition
Warm-up (40 sec) or Cool-down (60 sec)
Projection
The lamp cover or the air filter cover is detached.
Attach the cover securely.
The lamp operates abnormally.
Contact the qualified service personnel.
The fan is broken.
Contact the qualified service personnel.
The internal temperature is unusually high.
Wait until the projector cools down, and turn on the power again.
Filter Cover
15
Power
Lamp
Temp
Indicators