2-4. LOCATION

2-5. REFRIGERANT
INFORMATION
UL Specs
CE Specs

2-6. DRAIN CONNECTION

303
Place the cold tops in an area where product can be loaded and
unloaded without interruption. For proper operation, level the unit
by adjusting the bolts under the base, and leave 3 feet (91.44 cm)
clearance behind the unit for ventilation and service.
For maximum efficiency, units should be operated in an air-condi-
tioned environment, with maximum air temperature of 75° F
(24° C), and 55% relative humidity.
Wait at least 4 hours before plugging the unit into an
electrical supply. The gases and oils in the refrigeration
system needs to settle before operating the compressor, or
damage to the compressor could result.
Refrigerant Type Amount of Refrig.
CMC-103
R22
CMC-104
R22
CMC-105
R22
CMC-106
R22
CMC-107
R22
CMC-103
R134A
CMC-104
R134A
CMC-105
R134A
CMC-106
R134A
CMC-107
R134A
The cold tops-remote (CMRs), requires 1-1/2 inch (38.1 mm)
drain connection. CMCs do not require a plumbed drain.
Model CMC/CMR-103,104,105,106,107
1.5 lbs (0.680 kg)
440psig
(30.3 bar) (11.2 bar)
1.5 lbs (0.680 kg)
440psig
(30.3 bar) (11.2 bar)
2.5 lbs (1.134 kg)
440psig
(30.3 bar) (11.2 bar)
2.5 lbs (1.134 kg)
440psig
(30.3 bar) (11.2 bar)
2.5 lbs (1.134 kg)
440psig
(30.3 bar) (11.2 bar)
1.65 lbs (0.750 kg)
440psig
(30.3 bar) (11.2 bar)
1.87 lbs (0.850 kg)
440psig
(30.3 bar) (11.2 bar)
2.65 lbs (1.200 kg)
440psig
(30.3 bar) (11.2 bar)
3.09 lbs (1.400 kg)
440psig
(30.3 bar) (11.2 bar)
3.53 lbs (1.600 kg)
440psig
(30.3 bar) (11.2 bar)
Design Pressure
High
Low
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
2-3