Kenmore 141.16233 Operator's Manual page 17

Table of Contents

Advertisement

LP
Gas
Model
only:
Connect
Regulator
with
Hose
to your
LP Gas
Tank
[]
Turn
all
Burner
Valves
to
the
OFF
position.
[]
Inspect
the
valve
connection
port
and
regulator
assembly
for
damage
or
debris.
Remove
any
debris.
Never
use
damaged
or plugged
equip-
ment.
[]
Connect
the regulator
assembly
to the tank
valve
and HAND
TIGHTEN
nut clockwise
to a full stop.
DO NOT
use a wrench
to tighten
because
it could
damage
the
Quick
Coupling
Nut and
result
in a
hazardous
condition.
[]
Open
the tank
valve
1/4 to 1/2 of a turn
(coun-
terclockwise)
and
use
a soapy
water
solution
to
check
all connections
for
leaks
before
attempting
to light
your
grill.
See
"Checking
for
LP
Gas
Leaks".
If a leak is found,
turn
the tank
valve
off
and do not use your
grill until the leak is repaired.
Type 1 connection
per
ANSI Z21.58-2005/CGA
6b-2005
Quick
Coupling Nut
CAUTION:
When
the appliance
is not in use
the
gas
must
be turned
off at the tank.
Check all connections
for LP Gas Leaks
Never
test for
leaks
with
a flame.
Prior
to first
use,
at the beginning
of each
season,
or every
time
your
LP
Gas tank
is changed,
you
must
check
for
gas
leaks.
Follow
these
three
steps:
[]
Make
a soap
solution
by
mixing
one
part
liquid
detergent
and
one
part
water.
[]
Turn
the grill
Control
Knobs
to the full
OFF
position,
then
turn
the
gas
ON
at source.
[]
Apply
the
soap
solution
to all gas
connections
indicated
by the
arrows.
See
diagram.
If
bubbles
appear
in the
soap
solution
the
connections
are
not
properly
sealed.
Check
each
fitting
and
tighten
or repair
as
necessary.
Gas
Valve
/ Manifold
Assembly
Side Burner
Gas Vatve
Regulator with Hose (LPG)
LP Gas
Tank
If you
have
a gas
leak
that
cannot
be repaired
by tightening,
turn
off the gas
at the source,
disconnect
fuel
line from
your
grill
and
call
1-8O0-4-MY-HOME
® or your
gas
supplier
for
repair
assistance.
Disconnecting
A Liquid Propane Gas (LPG)
Tank From Your Grill
[]
Make
sure
the Burner
Valves
and
LP
Gas
tank
valve
are off.
(Turn
clockwise
to close.)
[]
Detach
the
hose
and
regulator
assembly
from
the
LP Gas
tank
valve
by turning
the Quick
Coupling
Nut
counterclockwise.
17