  • Page 1 Model 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 2 For Technical Support call 1-800-458-7062 Weigh Bar is a registered trademark of Weigh-Tronix Inc. ® 7820 B UPS Revenue Recovery Scale User’s Manual 07/30/03 7820B_U.P65 PN 55889-0018A e1 Printed in USA...
  • Page 3: Table Of Contents

    6” L x 3” D x 1½” H Platter Size: 14” L x 12½” D Power Supply: Input 120 VAC 60 Hz, Output 14VDC 750mA Battery: 12 VDC / 1.3AH Sealed Lead Acid Battery 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 4: Unpacking Your Scale

    Weights And Measures Sealing for details on how to configure the scale to deactivate the weight hold feature. Calibration may be required prior to Weights and Measures inspection. Please contact the service department at 1-800-458-7062 for the nearest dealer in your area. 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 5: Battery Operation

    (-) terminal, red cable to (+) terminal. Refit the cover and tighten the screws. Figure 1 Battery compartment Operation The NCI Model 7820 B has two keys to operate the scale plus a RESTART Keys pushbutton. See Figure 3. ZERO key The ZERO key performs three functions: 1.
  • Page 6: Sleep / Auto Shutdown Modes

    The scale will enter into sleep mode after 5 minutes of non-use. The scale display will prompt CHArG. Press the ZERO key to wake up the scale and return to normal weighing mode. The scale will return to zero weight within 5 seconds. 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 7: Backlight Operation

    2. When you place the next parcel on the parcel scale and weigh it. 3. SnGL Weight Hold automatically deactivates after 15 seconds. During Weight Hold operations, please allow the parcel weight to stabilize on the scale for at least 1 second. 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 8: Changing The Backlight Settings

    4. With the desired setting displayed, press the HOLD key once to accept the setting bACLt is displayed. 5. Press the ZERO key twice donE is displayed. 6. Press the HOLD key to exit and return to normal weighing mode. 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 9: Changing The Weight Hold Settings

    The 7820B powers up ready for weighing operations. Access the Menu Menu Mode mode by setting Switch 1, shown in Figure 4, to the OPEN or Menu mode position. To access Switch setting, remove the weight platter. Figure 4 Switch location 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 10 6. Press the ZERO key. . . SEALD is displayed. This stands for sealed. 7. Press the HOLD key to accept. . . Close Switch 1 to return to normal weighing mode. Figure 5 Mode menu structure 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 11: Cleaning And Care

    Display Cable, 7-feet 60014-0016 Foot w/ locking nut 60015-0015 Magnetic Strip, 6-inches 1101-16909 Handle, Kit 55880-0017 Battery Cover, Kit 55891-0014 Stainless Steel Weight Platter, Kit 55905-0018 Ball-Top Weight Platter Kit, Kit 55906-0017 7820 B UPS Revenue Recovery Scale User’s Manual...
  • Page 12 Avery Weigh-Tronix Avery Weigh-Tronix Canada, ULC 1000 Armstrong Dr. 217 Brunswick Boulevard Fairmont, MN 56031 USA Pointe Claire, QC H9R 4R7 Canada Telephone: 507-238-4461 Telephone: 514-695-0380 Facsimile: 507-238-4195 Toll free: 800-561-9461 e-mail: industrial@weigh-tronix.com Facsimile: 514-695-6820 www.wtxweb.com www.weigh-tronix.ca...