Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Weigh-Tronix reserves the right to change specifications at any time. 10/10/05 7800_U.P65 PN 7424-15170i e2 Printed in USA Model 7800 Family Weight Classifiers User’s Manual...
Specifications The NCI 7800 models are digital electronic parcel Description bench scales specifically designed for shipping applications and are Legal-for-Trade. The scales have built-in intelligence that enables them to be easily interfaced with a computer or other data- processing device.
Page 5
7885 (remote only) Key panel with ZERO and TEST keys. Optional remote display with 7 ft. cable. Level bubble located under weigh platter. Adjust- Scale Leveling able feet in each corner to level the scale. Model 7800 Family Weight Classifiers User’s Manual...
Page 6
The scale has 100,000 internal counts. Dynamic Response The time from when weight is applied to the scale until a stable weight display is displayed: 0–1000d 1.5 seconds 1000d+ 2.0 seconds maximum mean average Model 7800 Family Weight Classifiers User’s Manual...
Be sure the scale platter does not touch any adjacent surfaces. 2. To install the scale surface flush with a countertop, use the dimensions on the following page to guide construction. Model 7800 Family Weight Classifiers User’s Manual...
Page 8
4. Make sure all power cords, remote display cables, etc., are not touching the live weigh- ing surface. 5. Plug the unit into an appropriate voltage outlet that is properly grounded. Model 7800 Family Weight Classifiers User’s Manual...
“- - - -” If necessary, reapply Remove the item from the scale platter. power to reset the initial zero setting. Refer to the Trouble- shooting section if the problem persists. Model 7800 Family Weight Classifiers User’s Manual...
Page 10
CREASE key in the Gravity Mode. 7885 or Optional Remote Display All NCI 7800 bench scales, except the 7885, can have an optional remote display. If a remote display with keyboard is used, then Switch 3 (shown in Figure 1) determines which display keyboard is funcitional.
Page 11
The 7800 models power up ready for weighing Accessing the operations. Access the Menu mode by setting Menu Mode Switch 1 shown in Figure 1 or 2 to the OPEN or Menu mode position. Access the Gravity setting mode by setting...
Page 12
With Switch 2 in the Gravity Mode or OPEN Gravity Mode position, you may increase the local gravity value by pressing the ZERO key, or decrease the value by pressing the TEST key. Model 7800 Family Weight Classifiers User’s Manual...
Page 13
Figure 3 Menu Structure Model 7800 Family Weight Classifiers User’s Manual...
Page 14
The NCI 7800 bench scales allow calibration Alternative Calibration using less than full capacity weights. See Table 1 Points for alternative weights that can be used to calibrate your scale for its designated capacity. Table 1 Alternative Capacity Calibration Weights...
100,000 counts of displayed this special mode or resolution. AZT is disabled. power reset the scale. Areas to view current configuration settings are: Filter, Protocol, Baud, Capacity, Type, Units, Prtout and Gravity Setting. Model 7800 Family Weight Classifiers User’s Manual...
Page 16
7. Press the TEST key to perform the ROM test... PASS or FAIL is displayed briefly; then 8. Press the ZERO key... I/O is displayed. This stands for the INPUT/OUTPUT test. . Model 7800 Family Weight Classifiers User’s Manual...
Page 17
FILT is displayed. This stands for filter- menu to verify the ing. settings, but to make changes, you must 17. Press the TEST key... enter configuration or calibration. The current filter setting, FAST or SLO, is displayed. Model 7800 Family Weight Classifiers User’s Manual...
Page 18
25. Press the TEST key... The current rounding type, SCALE for standard rounding or CLASS for classi- fier rounding, is displayed. 26. Press the ZERO key... UNITS is displayed. This stands for unit- of-measure. Model 7800 Family Weight Classifiers User’s Manual...
Page 19
34. When you are finished, press the ZERO key, until DONE is displayed, then press the TEST key to return to the top menu level... DIAG is displayed. Or close Switch 1 to return to normal weigh- ing mode. Model 7800 Family Weight Classifiers User’s Manual...
1. From the DIAG display, press the ZERO key until CONF is displayed, or from the normal weighing mode, move Switch 1 to the Menu ode or the OPEN position; then press the ZERO key until CONF is displayed. Model 7800 Family Weight Classifiers User’s Manual...
Page 21
When the choice you want is available autoprint and displayed, press the TEST key... manual print modes of operation. The choice is accepted and the display shows PROT. Model 7800 Family Weight Classifiers User’s Manual...
Page 22
<CR> ..Represents the carriage return character (ØD hex) 14. When finished configuring your scale, press the ZERO key until DONE is displayed; then press the TEST keys, or close Switch 1 to return to the normal weighing mode. Model 7800 Family Weight Classifiers User’s Manual...
Page 23
TEST button can also be utilized for a remote push button to initiate the manual send se- quence. Model 7800 Family Weight Classifiers User’s Manual...
SCALE or CLASS – Selectable only when calibrated in LBS (lb) mode. Selection of SCALE rounds weight at 0.5 divisions. Selection of CLASS sets device up as a weight classifier rounding at 0.9 divisions. Model 7800 Family Weight Classifiers User’s Manual...
Page 25
TEST key... That choice is accepted and a scale capacity is displayed. Example: 100.02 If a different capacity selection is desired, press the ZERO key to scroll through the choices. Model 7800 Family Weight Classifiers User’s Manual...
Page 26
DIAG is displayed, or return Switch 1 to the closed position. The scale returns to normal weighing mode. The scale is now tested, configured, and cali- brated. It is ready for use in your application. Model 7800 Family Weight Classifiers User’s Manual...
.0002. When the correct value is displayed, simply return Switch 2 to the CLOSED position. The scale will now use this new relationship between calibration and local gravity for its weight calculations. Model 7800 Family Weight Classifiers User’s Manual...
5. When the choice you want is displayed, press the TEST key. 6. To change the capacity/resolution, press the ZERO key until RESO is displayed. 7. Press the TEST key. The current capacity/ resolution setting is displayed. Model 7800 Family Weight Classifiers User’s Manual...
To review the current system settings, press and hold the TEST key until the display shows, “ - - - - - - - - “. Model 7800 Family Weight Classifiers User’s Manual...
Page 30
When finished running tests or viewing the settings, press the ZERO key until DONE is displayed. Then press the TEST key to return to normal (i.e., weighing) mode of operation. Model 7800 Family Weight Classifiers User’s Manual...
Communication The NCI 7800 family scales come factory config- ured as a serial RS-232 interface device. There is one 9-pin DE type female connector accessible at the rear of the unit. The functional pinout of this connector is compatible with a standard PC with a pass through cable.
Page 32
Standard Commands Scale Response <LF>xxxx.xxuu<CR> <LF>hh<CR><ETX> Results Returns decimal weight with units plus scale status. S<CR> Scale Response <LF>hh<CR><ETX> Results Returns to scale status. Z<CR> Scale Response <LF>hh<CR><ETX> Results Scale is zeroed, returns status. Model 7800 Family Weight Classifiers User’s Manual...
Page 33
(div-A) <CR> xxxxxx (div-n) <CR> Results Returns weight normalized to 100,000 division with AZT on/off. Protocol must be set for NCI and the scale must be in the “DIAG” (diagnostics) sub-menu. Otherwise, the scale will respond with the unrecognized command response.
The error codes are broken down into two hexadecimal numbers, with each bit defining a single error condition. The error codes are defined as follows: Model 7800 Family Weight Classifiers User’s Manual...
Display shows unrecognized characters 1. Check software PROM for proper insertion. 2. Check display cables for the proper connec- tion. 3. Replace PROM. 4. Replace the display board. 5. Replace the main board. Model 7800 Family Weight Classifiers User’s Manual...
Page 36
1. Check cable connection at both the rear of the scale and the host device. 2. Check communication setting and baud rate on both scale and software. 3. Perform I/O loopback test. Model 7800 Family Weight Classifiers User’s Manual...