Underwriters Laboratories Listed
Homologué Underwriters Laboratories
WARNING: If the information in these
instructions is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
death.
- Do not store or use gasoline or other
flammable vapors and liquids in the vi-
cinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
- Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.
1. This appliance may be installed in an after-
market, permanently located, manufactured
(mobile) home, where not prohibited by local
codes.
2. This appliance is only for use with the type of
gas indicated on the rating plate. This appli-
ance is not convertible for use with other
gases, unless a certified kit is used.
Installers Guide
Guide d'installation
Models/Modèles :
Grand-XT, Supreme-XT
1
AVERTISSEMENT : Si ces instructions
ne sont pas suivies à la lettre, un
incendie ou une explosion pourraient en
résulter, causant des dommages
matériels, des blessures ou la mort.
- N'entreposez ou n'utilisez jamais
d'essence ou autres vapeurs et liquides
inflammables à proximité de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ :
• Ne tentez d'allumer aucun appareil.
• Ne touchez aucun interrupteur
électrique.
• N'utilisez aucun téléphone dans votre
édifice.
• Appelez
immédiatement
fournisseur de gaz vous servant du
téléphone d'un voisin. Suivez les ins-
tructions du fournisseur de gaz.
• Si vous ne pouvez pas atteindre votre
fournisseur de gaz, appelez le service
des incendies.
- L'installation et l'entretien doivent être
effectués par un installateur qualifié, une
agence de maintenance ou le four-
nisseur de gaz.
1. Cet appareil peut être installé dans un mobile
home préfabriqué, qui a été vendu et ne sera
plus déplacé, si les codes locaux l'autorisent.
2. Cet appareil est conçu pour être utilisé
seulement avec le type de gaz indiqué sur la
plaque signalétique. Cet appareil ne peut être
converti à l'utilisation d'autres gaz qu'avec un
module homologué.
votre
349-901EF 10/03

Advertisement

Table of Contents
loading

Summary of Contents for Hearth and Home Technologies Grand-XT

  • Page 1 Installers Guide Guide d’installation Models/Modèles : Grand-XT, Supreme-XT AVERTISSEMENT : Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient en résulter, causant des dommages matériels, des blessures ou la mort.
  • Page 2: Safety And Warning Information

    WARNING: Improper installation, ad- justment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual. For assistance or additional informa- tion consult a qualified installer, service agency or the gas supplier. Read this manual before installing or operating this appliance.
  • Page 3 NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations. Due to the high temperature, the appliance should be LOCATED out of traffic areas and away from furniture and draperies.
  • Page 4: Table Of Contents

    Table of Contents Safety and Warning Information ... 2 Service Parts List ... 5 Section 1: Approvals and Codes... 10 Approval Listing and Codes ... 10 Appliance Certification ... 10 Installation Codes ... 10 High Altitude Installations ... 10 Section 2: Getting Started ... 11 Introducing the Hearth &...
  • Page 5: Service Parts List

    Grand-XT, Supreme-XT Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-02 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ Part number list on following pages. / La liste des numéros de pièce se trouve à la page suivante.
  • Page 6 Burner Orifice NG (#32C) / Orifice de brûleur GN (#32C) Burner Orifice LP (#51C) / Orifice de brûleur PL (#51C) Flex Pipe Handle / Fléchissez Poignée de Pipe Also see Standing Pilot Ignition service part numbers on following page. DESCRIPTION GRAND-XT PART NUMBER / N° DE PIÈCE 319-213A 107-500A...
  • Page 7 (NG , LP) Service Parts List / Liste des pièces de rechange IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 8: Service Parts

    Pilot Assembly LP / Module de veilleuse PL Thermopile / Thermopile Service Parts (NG, LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces DESCRIPTION Grand-XT, Supreme-XT Beginning Manufacturing Date: 4-02 Ending Manufacturing Date: ______ SERIAL # PART NUMBER / N° DE SÉRIE / N°...
  • Page 9 Log 5 / Bûche 5 Log 6 / Bûche 6 Log 7 / Bûche 7 Log Set Assembly / Jeu de Bûche LOGS-GXT LOGS-SXT PART DESCRIPTION PART NUMBER / N° DE PIÈCE Grand-XT Supreme-XT SRV339-701 SRV349-701 SRV339-702 SRV349-702 SRV327-703 SRV327-703...
  • Page 10: Section 1: Approvals And Codes

    Appliance Certification The Hearth & Home Technologies models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICATION STANDARD MODELS Grand-XT, Supreme-XT LABORATORY Underwriters Laboratories TYPE Direct Vent Gas Fireplace Heater STANDARD ANSI Z21.88•CSA2.33•UL307B...
  • Page 11: Section 2: Getting Started

    Getting Started Introducing the Hearth & Home Technologies Gas Appliances Hearth & Home Technologies direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. The information contained in this Installers Guide, unless noted otherwise, applies to all models and gas con- trol systems.
  • Page 12: Venting And Installation

    Getting Started (continued) VENTING AND INSTALLATION 1. Hearth & Home Technologies gas inserts are designed for recessed installations into solid fuel Masonry or Fac- tory Built Non Combustible fireplaces that have been in- stalled in accordance with the National, Provincial, State and local building codes.
  • Page 13 Getting Started (continued) 7. To assure top performance, safety and efficiency, inserts must be installed with an approved flue liner as per CAN/ CGA B-149 or National Fuel Code ANSI Z223 and these instructions. WARNING: THE SOLID FUEL FIREPLACE HAS BEEN CONVERTED FOR USE WITH GAS ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL PARTS...
  • Page 14 • Si vous désirez installer des accessoires facultatifs (dispositifs tels qu’un interrupteur mural ou une commande à distance). Figure 1. 4-7/16 5-5/32 112.4 130.7 8-7/16 214.5 MODEL DIMENSIONS Grand-XT Inches Milimeters 33-1/32 24-1/4 12-1/8 36-7/8 14-3/4 685.8 22-3/4 23-11/16 (suite) Schéma...
  • Page 15 Location (suite) Schéma de la cassette INLET AIR STARTING COLLAR / COLLIER DE DEPART D’ADMISSION D’AIR COLLAR / ELECTRICAL JUNCTION BOX ACCESS / ACCÈS DE BOÎTE DE JONCTION ÉLECTRIQUE Grand-XT Supreme-XT Inches Milimeters Inches 33-1/4 29-1/4 24-1/4 20-1/4 13-5/8 13-5/8...
  • Page 16: Section 3: Installing The Insert

    Installing the Insert Step 1 Installing the Vent System Vent System Installation Precautions Before starting installation of vent kits, the installer should read these instructions and the Vent Kit Instructions to ensure that a proper vent installation is completed. Consult your local Building Codes before beginning the Installation.
  • Page 17 Installing the Insert (continued) NOTE: The damper of the masonry chimney may need to be removed to allow installation of the flexible-vent pipe. WARNING: THE SOLID FUEL FIRE- PLACE HAS BEEN CONVERTED FOR USE WITH GAS ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UN- LESS ALL ORIGINAL PARTS HAVE BEEN RE- PLACED AND THE FIREPLACE HAS BEEN...
  • Page 18 Installing the Insert (continued) WARNING: MAJOR U.S. BUILDING CODES SPECIFY MINIMUM CHIMNEY AND/OR VENT HEIGHT ABOVE THE ROOF TOP. MINIMUM HEIGHTS ARE NECESSARY IN THE INTEREST OF SAFETY. SEE THE FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS, PROVIDED THE TERMINATION CAP IS AT LEAST 2-FEET FROM A VERTICAL WALL AND 2 FEET BELOW A HORIZONTAL OVERHANG.
  • Page 19 Installing the Insert (continued) Figure 4. WARNING: THE EXHAUST PIPE MUST ONLY BE CONNECTED TO THE EXHAUST STARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINATION CAP. THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNIT AND EI- THER ATTACHED TO THE INLET AIR COLLAR OF THE TERMINATION CAP OR TERMINATED IN THE CHIMNEY.
  • Page 20 Installing the Insert Installation de la cassette (continued) (suite) TERMINATION CAP (CAPUCHON) INLET AIR COLLAR (COLLET D’ADMISSION D’AIR) ADAPTOR (RACCORD) EXHAUST COLLAR (COLLET D’EVACUATION) INLET AIR STARTING COLLAR (COLLET DE RACCORD DU CONDUIT D’ADMISSION D’AIR) STARTING COLLAR BRACKET (COLLET DE RACCORD DU CONDUIT CROCHET) EXHAUST STARTING COLLAR (COLLET DE RACCORD DU...
  • Page 21: Step 2 Positioning, Leveling, And Securing The Insert

    Installing the Insert (continued) Step 2 Positioning, Leveling, and Securing Insert 1. Place the insert into position. 2. Level the insert from side to side and from front to back. • If necessary use the leveling bolts included in the manual bag.
  • Page 22: Step 4 The Gas Supply Line

    Installing the Insert (continued) Step 4 The Gas Supply Line NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).
  • Page 23: Step 5 Gas Pressure Requirements

    Installing the Insert (continued) Step 5 Gas Pressure Requirements Pressure Natural Gas Minimum 5.0 inches Inlet Pressure w.c. Maximum Inlet 14.0 inches Gas Pressure w.c. Manifold 3.5 inches Pressure w.c. A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping is provided on the inlet and outlet side of the gas control for a test gauge connection to measure the manifold pressure.
  • Page 24: Step 6 Wiring The Fireplace

    Installing the Insert (continued) Step 6 Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENTAL FIREPLACE OPERATION. For Standing Pilot Ignition Wiring Appliance Requirements •...
  • Page 25 Installing the Insert (continued) WARNING: DO NOT CONNECT 1 10-120 VAC TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA- TION.
  • Page 26: Step 7 Installing Logs And Ember Material

    Replacez la porte en verre. Insérez ensuite les languettes du haut de la porte en verre dans les fentes situées en haut du foyer. Pour le modèle Grand-XT, faites glisser les languettes du haut sous les verrous à ressort du haut.
  • Page 27 Installing the Insert (continued) 1. Lift the top trim door up and out of the unit. 2. Unlatch and remove the glass door from the unit. Figure 11. Glass Assembly 1. Place a single layer of dime sized pieces of ember mate- rial onto the top of the burner.
  • Page 28: Step 8 Installing The Trim Surrounds

    Installing the Insert (continued) Step 8 Installing the Trim Surrounds Combustible materials MUST NEVER overlap onto the front face. WARNING: WHEN FINISHING THE FIREPLACE INSERT, NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET GRILLES ON THE INSERT IN ANY MANNER. SURROUND WITH TRIM /ENTOURAGE A GARNITURE /PORTE DE GARNITURE Figure 13...
  • Page 29 Installing the Insert (continued) 4. Slide the surround against the face of the unit, aligning the holes in upper and lower, right and left corners and secure the surround to the unit with the attachment screws. NOTE: PLACE THE THREE INSULATION PIECES INTO THE CAVITIES AT THE BACK OF THE SURROUND BEFORE POSITIONING THE INSERT INTO THE FACTORY- BUILT OR MASONRY FIREPLACE.
  • Page 30: Step 9 Before Lighting The Appliance

    Installing the Insert (continued) Step 9 Before Lighting the Appliance Before lighting the appliance, do the following: Review safety warnings and cautions • Read the Safety and Warning Information section at the beginning of this Installers Guide. Double-check for gas leaks •...
  • Page 31: Step10 Lighting The Appliance

    Step 10 Lighting the Appliance You’ve reviewed all safety warnings, you’ve checked the appliance for gas leaks, you know the vent system is unobstructed, and you’ve checked for faulty components. Now you’re ready to light the appliance. WARNING: PLEASE REFER TO THE USER’S MANUAL FOR ALL CAUTIONS, SAFETY AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERA TION OF THE APPLIANCE.
  • Page 32 Maintaining and Servicing Your Appliance (continued) Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician. Task: Brush or vacuum the control compartment, fireplace logs and burner areas surrounding the logs. Checking Flame Patterns, Flame Height Frequency: Periodically. By: Qualified service technician/Home owner. Task: Make a visual check of your fireplace’s flame patterns.