6. "FUSE" (MAIN FUSE) Input Light Emitting Diode (L.E.D.) Indicator
a. Should be on ALL the time (even if the dryer is not running. If the L.E.D. is not on; then the display
will read "CHECK MAIN FUSE." If the main fuse is good then the fault is on the Phase 6 microprocessor
controller (computer).
7. "LINT" (LINT DOOR) Input L.E.D. Indicator
a. Should be on ALL the time (unless the lint door is opened then the "LINT" L.E.D. indicator will go
out).
b. If the dryer is active (running) and the lint door is opened the "LINT" L.E.D. indicator will go out and
the display will read "LINT dOOR." The dryer will stop until the Lint Drawer has been closed, at
which time the L.E.D. display will read "PRESS START." At this time, to resume the drying cycle
press and "ENTER/START"
8. "MAIN" (MAIN DOOR) Input L.E.D. Indicator
a. Should be on ALL the time (unless the lint door is open or the main door is opened then the "MAIN"
L.E.D. indicator will go out).
b. If the dryer is active (running) and the main door is opened the "MAIN" L.E.D. indicator will go out and
the display will read "MAIN dOOR." The dryer will stop until the Main Door has been closed, at which
time the L.E.D. display will read "PRESS START." At this time, to resume the drying cycle press and
"ENTER/START"
9. "DRUM" (BASKET [TUMBLER] HI-LIMIT) Input L.E.D. Indicator
a. Should be on at ALL times (unless the basket [tumbler] hi-limit switch opens prior during the cycle
while the heat was on the display would read "dRUM SAFETY FAIL"). The dryer will run with no
heat for 3 minutes or until the temperature drops below 100º F. Then the dryer will shut down still
displaying "dRUM SAFETY FAIL" with an audio indication.
10. "SAIL" (SAIL SWITCH) Input L.E.D. Indicator
a. This routine will prevent start up on the dryer unless the sail switch is in the correct position. If the sail
switch is in the closed position prior to start, the "SAIL" output L.E.D. indicator will be off, the dryer
will not start and the display will read "SAIL SWITCH FAIL" along with an audio indication.
b. If the sail switch opens during the cycle the "SAIL" output L.E.D. indicator will go out and the display
will read "NO AIRFLOW." The dryer will run with no heat for 3 minutes or until the temperature drops
below 100º F. Then the dryer will shut down still displaying "NO AIRFLOW" along with an audio
indication.
11. "BURN" (BURN HI-LIMIT) Input L.E.D. Indicator
a. This routine monitors the temperature of the burner. If the burner hi-limit opens during the cycle while
the heat was on the "BURN" output L.E.D. indicator goes out and the display reads "bURNER SAFETY
FAIL." The dryer will run with no heat for 3 minutes or until the temperature drops below 100º F then
the dryer will shut down still displaying "bURNER SAFETY FAIL" with an audio indication.