LAIMS ............................... 23 ECHNICAL PECIFICATIONS CHAUVET®, 2012, All Rights Reserved Information and specifications in this User Manual are subject to change without notice. CHAUVET® assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual.
Safety Instructions Please read these instructions carefully. It includes important information about the installation, usage and maintenance of this product. · Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
2. I NTRODUCTION Features · 3, 4, 6, 7, 12 or 24-channel DMX-512 LED linear wash light · Operating modes: 3-channel: RGB control 4-channel: RGB, dimmer 6-channel: RGB control of 2 sections 7-channel: RGB, macros, run/strobe speed, automatic/sound, dimmer 12-channel: RGB control of 4 sections (each pair) 24-channel: RGB control of 8 sections (each LED) ·...
Product Overview Bracket Adjustment Knobs(2) Single-yoke Hanging/Standing Brackets (2) Double-yoke hanging bracket Power Link Out Control Board Power Microphone In/Fuseholder Adjustment Knob DMX In DMX Out 2. Introduction 2/6/2012 2:58 PM...
3. S ETUP AC Power This fixture runs on 100~240 VAC, 50/60 Hz. Before powering on the unit, make sure the line voltage to which you are connecting it is within the range of accepted voltages. Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only as a 0 to 100% switch.
Disconnect the power cord before replacing a fuse and always replace with the same type fuse. Fuse Replacement With a flat head screwdriver wedge the fuse holder out of its housing. Remove the damaged fuse from its The fuse is located holder and replace with exact same type inside this fuse.
4. O PERATING NSTRUCTIONS Configuring the Starting Address Each fixture requires a starting address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the starting address. For example, a fixture that uses seven DMX channels and is addressed to start on DMX channel 100, will read data from channels: 100, 101, 102, 103, 104, 105 and 106.
Menu Map UNCTION UNCTION ELECTION ELECTION NSTRUCTION 7 Color Switching 7 Color fading Select between 2 switching, 2 fading built-in 3 Color Switching programs, and a chase program 3 Color Fading Chase Program Use the Audio Adjustment 7 Color sound active Knob located on the back Select between 1 sound active program of the fixture...
DMX Operation This is the operating mode which will allow for control with an external DMX controller. You must set the starting address for this mode. If this is your first time using DMX, then it is recommended that you refer to the “DMX Primer”...
Standalone Operation Automatic This fixture has preprogrammed chases. These are accessed via the control panel, and the speed may be adjusted for the chases. Please see the instructions below for further explanation. Press <MENU> until appears on the LED screen. Press <ENTER>.
Fixture Linking In order to use this fixture in a DMX or master/slave operation, you must daisy chain using DMX cables to link from one fixture to another. In a master/slave operation, the DMX controller is not connected. Fixture #1 DMX controller (only in DMX operation) Fixture #2...
DMX Channel Values 7-CH Mode HANNEL ALUE UNCTION 000 ó 255 Dimmer: 0%~100% Green 000 ó 255 Dimmer: 0%~100% Blue 000 ó 255 Dimmer: 0%~100% Color Macros 000 ó 015 No Function 016 ó 255 Color Macros Speed (CH.6 @ values 032~223) 000 ó...
Page 15
4-CH Mode HANNEL ALUE UNCTION 000 ó 255 Dimmer: 0%~100% Green 000 ó 255 Dimmer: 0%~100% Blue 000 ó 255 Dimmer: 0%~100% Dimmer 000 ó 255 Intensity: 0%~100% 6-CH Mode HANNEL ALUE UNCTION ECTION 000 ó 255 Dimmer: 0%~100% Green 000 ó...
12-CH Mode HANNEL ALUE UNCTION ECTION 000 ó 255 Dimmer: 0%~100% Green 000 ó 255 Dimmer: 0%~100% Blue 000 ó 255 Dimmer: 0%~100% 000 ó 255 Dimmer: 0%~100% Green 000 ó 255 Dimmer: 0%~100% Blue 000 ó 255 Dimmer: 0%~100% 000 ó...
Page 17
24-CH Mode HANNEL ALUE UNCTION ECTION HANNEL ALUE UNCTION ECTION 000 ó 255 000 ó 255 Dimmer: 0%~100% Dimmer: 0%~100% Green Green 000 ó 255 000 ó 255 Dimmer: 0%~100% Dimmer: 0%~100% Blue Blue 000 ó 255 000 ó 255 Dimmer: 0%~100% Dimmer: 0%~100% 000 ó...
5. A PPENDIX DMX Primer There are 512 channels in a DMX connection. Channels may be assigned in any manner. A fixture capable of receiving DMX will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required.
Data Cabling To link fixtures together you must obtain data cables. You can purchase CHAUVET® certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
3-Pin to 5-Pin Conversion Chart If you use a controller with a 5-pin DMX output connector, you will need to use a 5- pin to 3-pin adapter. The chart below details a proper cable conversion: IN TO ONVERSION HART Conductor 3-Pin Female (Output) 5-Pin Male (Input) Ground/Shield...
· Install an optically coupled DMX splitter after unit #32 · Keep DMX cables separated from power cables or · Interference from AC wires black lights If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support. Contact Us Wor l d Wi de...
Package must be clearly labeled with a Return Merchandize Authorization Number (RMA #). Products returned without the RMA # will be refused. Call CHAUVET® and request an RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
Technical Specifications WEIGHT & DIMENSIONS Length ........................... 41.6 in (1,056 mm) Width ............................ 2.3 in (59 mm) Height ..........................5.9 in (148 mm) Weight ..........................7.1 lbs (3.2 kg) POWER Auto-ranging Power Supply ................100~240 VAC, 50/60 Hz Power Consumption @ 120 VAC, 60 Hz ..........41 W (0.6 A) max, 0.2 A inrush Power Consumption @ 230 VAC, 50 Hz ..........41 W (0.3 A) max, 0.2 A inrush Power output ...........................