Before Wiring Humidifier; Step One: Remove The Humidifier Cover; Step Two: Understand The Wiring Terminals - Honeywell HE100 Professional Installation Manual

Humidifier
Table of Contents

Advertisement

Available languages

Available languages

Before Wiring the Humidifier
CAUTION: Voltage Hazard.
Be sure the humidifier is not plugged in before beginning wiring.
Before wiring the humidifier:
I understand and will comply with applicable local wiring codes and regulations.
I will read the section "Using the DIP Switches" beginning on the next page.
What humidifier model do I have?
The model number can be found on the bottom of the humidifier.
STEP ONE:
Remove the Humidifier Cover
STEP TWO:
Understand the Wiring Terminals (HE150/HE250/HE300 only)
HE150/HE250 Bypass Terminal
HE300 Fan Terminal
Humidifier 69-2413EF—01
Remove the bottom cover.
1a
MCR29935
MCR29937
M29936
Gf:
Used to force system fan on when humidity is
needed.
R:
Input from system R. Needed to power Gf when
forcing fan on.
Gt or W:
Input from system G or W. Needed to
humidify only during fan or heat calls by system.
HUM:
Dry contacts for humidity control.
C:
Common. Needed for Gt or W input. Connect to
system C.
Power Out:
24V power for electric controls.
Power In:
Power from 15VA transformer on HE150/
HE250 only.
SENSOR:
Dry contacts for air proving device.
1b
MCR29950
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

He150He200He250He300

Table of Contents