Ensuring proper ventilation
Proper ventilation for the system is important for workstation operation. Follow these guidelines to
ensure adequate ventilation:
Operate the workstation on a sturdy, level surface.
●
Place the workstation in an area with adequate ventilation. Provide at least 15.24 CM (6 inches)
●
of clearance at the front and back of the workstation as shown in the following figure.
Your workstation might look different than the one shown.
Figure 1-6
Ensure that the ambient air temperature surrounding the workstation falls within the published limit.
●
NOTE:
is a 1 C per 304.8 M (1000 FT) derating above 1524 M (5000 FT). So, at 3,048 M (10,000
FT), the upper ambient air temperature limit is 30 C.
For cabinet installation, ensure adequate cabinet ventilation and ensure that the ambient
●
temperature within the cabinet does not exceed published limits.
16
Chapter 1 Product overview
Proper workstation ventilation
The ambient upper limit of 35 C is only good up to 1524 M (5000 FT) elevation. There