Solar thermal domestic hot water system
Hide thumbs Also See for Solarflo:

Advertisement

Please leave these instructions with the user for safe keeping.
User Guide
Solarflo - Solar Thermal Domestic Hot Water System
© Baxi Heating UK Ltd 2007.

Advertisement

loading

Summary of Contents for Baxi Solarflo

  • Page 1 Please leave these instructions with the user for safe keeping. User Guide Solarflo - Solar Thermal Domestic Hot Water System © Baxi Heating UK Ltd 2007.
  • Page 2 Baxi Technical Enquiry Line, Telephone 08700 603261. © BAXI Heating UK Ltd 2007. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature...
  • Page 3 60% of a dwellings annual hot water requirement can be provided by a solar water heating system.The balance is provided by the auxiliary heating source. Fig 1 shows the main component parts of the Baxi Solarflo System. 1 Solar panel...
  • Page 4: System Operation

    System operation Generally the operating settings of your Baxi Solarflo Domestic hot water heating system will have been set up by your installer. For the system to operate correctly and efficiently these settings should not be altered. Section 4 details the user controls which your installer should familiarise you with during commissioning the system.
  • Page 5 Appears when switch output 3 is active (on) Reference to system fault Display flashes when a fault occurs in the system Input value can be either Safety query for value changes which are to be stored rejected or accepted Solarflo - Solar Thermal Domestic Hot Water System...
  • Page 6 3.0 of the Commissioning, Maintenance and Servicing Guide. NOTE: Altering some settings could adversely affect the operation of the Solarflo system, if in doubt contact a qualified solar installation engineer. Alteration of functions, not covered in this user guide will invalidate the warranty.
  • Page 7 • Connection with flow • Check wire Additionally at energy meter defect productivity measurement: • Sensor wire broken • Check wire • Sensor defect • Check sensor resistance, if necessary exchange sensor Solarflo - Solar Thermal Domestic Hot Water System...
  • Page 8: Important Notes

    Additionally the concentration of the solar thermal B AX I transfer fluid should be checked and if necessary, A Trading Division of Baxi Heating UK Ltd, a division of Baxi Group. topped up or replaced every 2 years. Failure to Brooks House, Coventry Road,Warwick. CV34 4LL maintain the system may invalidate your warranty.