Io_Psu; Io_Fan; Led Mounting Locations; F.1.14 Io_Psu - Fujitsu PRIMEQUEST 2000 Series Administration Manual

Primequest 2000 series
Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

Appendix F Status Checks with LEDs
F.2

F.1.14 IO_PSU

The IO_PSU comes equipped with the following LEDs.
LED type
AC
Green
DC
Green
CHECK
Orange
AC input to all IO_PSUs is off.
AC input to the IO_PSU is off, and AC input to another
IO_PSU is on.
AC input is on, and the IO_PSU is off (+5 V standby being
output).
AC input is on, and the IO_PSU is on (+5 V standby being
output, +12 V being output).
There is an IO_PSU output error (+5 V standby being output,
+12 V output error).
There is an IO_PSU output error (+5 V standby output error,
+12 V being output).
There is an IO_PSU output error (+5 V standby output error,
+12V output error).

F.1.15 IO_FAN

The IO_FAN comes equipped with the following LEDs.
LED type
Alarm
Status
Error in IO_FAN
F.2

LED Mounting Locations

This section describes the physical LED mounting locations on each component.
-
Components equipped with Power, Alarm, and Location LEDs have the LEDs mounted as follows.
-
The order of mounted LEDs arranged from left to right is as follows: Power, Alarm, Location.
-
The order of mounted LEDs arranged from top to bottom is as follows: Power, Alarm, Location.
-
From the standpoint of appearance, components equipped with LAN ports have the Speed LED on the
left and the Link/Act LED on the right of each port.

FIGURE F.1 LED mounting locations on components equipped with LAN ports

LED Mounting Locations

TABLE F.23 IO_PSU LED

Color
Indicates whether there is AC input to the
individual PSU.
Indicates the on/off status of each IO_PSU.
Indicates whether there is an error in the

IO_PSU.

TABLE F.24 IO_PSU status and LED display

Status

TABLE F.25 IO_FAN LED

Color
Orange
Indicates whether there is an error in the IO_FAN.

TABLE F.26 IO_FAN status and LED display

Function
AC
Off
Off
On
On
On
Off
Off
Function
262
Note
IO_PSU control
IO_PSU control
MMB-FW control
DC
CHECK
Off
Off
Off
Off
Off
Off
On
Off
Off
On
On
On
Off
On
Alarm
On
C122-E175-02EN