Compatible Systems DS3- Quad 10/100 RIOP Installation Manual

Routing input/output processor
Table of Contents

Advertisement

Quick Links

DS3- Quad 10/100 RIOP Installation Guide
Compatible Systems Corporation
4730 Walnut Street
Suite 102
Boulder, Colorado 80301
303-444-9532
800-356-0283
http://www.compatible.com

Advertisement

Table of Contents
loading

Summary of Contents for Compatible Systems DS3- Quad 10/100 RIOP

  • Page 1 DS3- Quad 10/100 RIOP Installation Guide Compatible Systems Corporation 4730 Walnut Street Suite 102 Boulder, Colorado 80301 303-444-9532 800-356-0283 http://www.compatible.com...
  • Page 2 DS3-Quad 10/100 RIOP Installation Guide, Version 1.0 Copyright© 1999, Compatible Systems Corporation All rights reserved. VSR, VSR-2, MicroRouter and CompatiView are trademarks of Compatible Systems Corporation. Other trademarks are the property of their respective holders. FCC Notice: This product has been certified to comply with the limits for a Class A computing device, pursuant to Subpart J of Part 15 of FCC Rules.
  • Page 3: Table Of Contents

    Table of Contents Introduction to the DS3-Quad 10/100 RIOP Chapter 1 - Network Installation Connecting the DS3-Quad 10/100 to the Ethernet DS3 Line Connection Requirements Connecting the DS3-Quad 10/100 to a DS3 Line Connecting a Management Console Powering Up the Router Chapter 2 - Quickstart Instructions THERNET NTERFACE...
  • Page 4 Table of Contents IP Protocol Required for IP Numbered Interface Required for IP Unnumbered Interface Suggested for IP IPX Protocol Required for IPX Suggested for IPX AppleTalk Protocol Required for AppleTalk Suggested for AppleTalk DECnet Protocol Required for DECnet SMDS Configuration Link Configuration Suggested for Dedicated/Leased Line Operation SMDS Addressing...
  • Page 5: Introduction To The Ds3-Quad 10/100 Riop

    Introduction to the DS3-Quad 10/100 RIOP Introduction to the DS3-Quad 10/100 RIOP The DS3-Quad 10/100 Routing Input/Output Processor (RIOP), as part of the VSR multigi- gabit switching router, allows you to connect a remote corporate network and up to four local Ethernet segments.
  • Page 6: Chapter 1 - Network Installation

    These cables require special tools to be built correctly. You can use your approved cable supplier or you can contact your reseller or your Compatible Systems representative for a list of cable suppliers. To have a cable built, use the following specifications: •...
  • Page 7: Connecting The Ds3-Quad 10/100 To A Ds3 Line

    1 stop bit and no Flow Control. v Note: The DS3-Quad 10/100 RIOP also has an AUX interface. This is a modem connection which should only be used in consultation with Compatible Systems Technical Support staff, who will provide instruction on its use.
  • Page 8: Chapter 2 - Quickstart Instructions

    Chapter 2 - Quickstart Instructions Chapter 2 - Quickstart Instructions This Quickstart chapter briefly discusses the major parameters that must be set in order to use the DS3-Quad 10/100 RIOP as part of your VSR multigigabit switching router. Detailed information on the meaning of the router’s parameters is provided in the Compa- tiView Management Software Reference Guide and the Text-Based Configuration and Command Line Management Reference Guide.
  • Page 9: Suggested For Ip

    Chapter 2 - Quickstart Instructions Suggested for IP These parameters help supply information about the segment that the interface is connected to. With this information, routing can take place. • Set IP RIP 1, IP RIP 2 or OSPF (Open Shortest Path First) •...
  • Page 10: Suggested For Decnet

    Chapter 2 - Quickstart Instructions numbers you wish to configure) section. Use configure and set the Enabled, Area, and Node keywords in the DECnet Global section. v Note: Setting DECnet on for any port with the command line also sets DECnet on globally. In CompatiView you must set a global parameter and a port-specific parameter.
  • Page 11: Ipx Protocol

    Note: Due to the complexity of BGP, configuration parameters for BGP are not given in this Quickstart. For help with BGP configuration parameters, and other configuration questions, refer to the Tech Support pages on the Compatible Systems Web site at: http://www.compatible.com/.
  • Page 12: Suggested For Dedicated Line Operation

    Dedicated line operation generally does not require additional parameters for operation. Frame Relay DLCI Mappings If you are connecting to another Compatible Systems router, this information is not required for Frame Relay operation. Compatible Systems uses IARP (Inverse Address Resolution Protocol) to dynamically generate this information.
  • Page 13: Required For Ipx

    Note: Due to the complexity of BGP, configuration parameters for BGP are not given in this Quickstart. For help with BGP configuration parameters, and other configuration questions, refer to the Tech Support pages on the Compatible Systems Web site at: http://www.compatible.com/.
  • Page 14: Smds Configuration

    Chapter 2 - Quickstart Instructions TB: Use configure and set the Mode keyword in the DECnet WAN 0 section. v Note: Setting DECnet on for any port with the command line also sets DECnet on globally. In CompatiView you must set a global parameter and a port-specific parameter. SMDS Configuration This section covers the settings required for SMDS (Switched Multi-megabit Data Service) operation of the DS3 WAN interface (IP only).
  • Page 15: Chapter 3 - Shipping Defaults

    Chapter 3 - Shipping Defaults Chapter 3 - Shipping Defaults Ethernet Interfaces IP Routing Defaults • Off, all interfaces IP Bridging Defaults • On, all interfaces • Address: 198.41.12.1 • Subnet Mask: 255.255.255.0 • Broadcast Address: 198.41.12.255 • IP RIP off IPX Routing Defaults •...
  • Page 16: Chapter 4 - Led Patterns

    In addition to indicating certain router-wide operating conditions, they can also display port-specific information. v Note : Any continuous flashing pattern not noted in this chapter may be caused by a hard- ware failure. Please call Compatible Systems Technical Support if your router shows a hard- ware failure. Router LED Patterns The following LEDs and light patterns provide information about the VSR’s physical state and...
  • Page 17: Ds3-Q Uad 10/100 Riop Led P Atterns

    Chapter 4 - LED Patterns DS3-Quad 10/100 RIOP LED Patterns The following LEDs and light patterns provide information about the DS3-Quad 10/100 RIOP interfaces. Ethernet Traffic Indicators Scan from 1 to 3: Ethernet transmit packet Scan from 5 to 3: Ethernet receive packet DS3 Indicators Scan from 1 to 3: WAN transmit packet Scan from 5 to 3: WAN receive packet...