Electromagnetic Immunity - Maxtor STM3320820A Owner's Manual

200 - 320gb pata model drives
Table of Contents

Advertisement

2.11

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 7:
Radio frequency environments
Test
Electrostatic discharge
Radiated RF immunity
Electrical fast transient
Surge immunity
Conducted RF immunity
Voltage dips, interrupts
DiamondMax 21 PATA Product Manual, Rev. A
Description
Contact, HCP, VCP: ± 4 kV; Air:
± 8 kV
80 to 1,000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse
modulation @ 200 Hz
± 1 kV on AC mains, ± 0.5 kV on
external I/O
± 1 kV differential, ± 2 kV com-
mon, AC mains
150 kHz to 80 MHz, 3 Vrms,
80% AM with 1 kHz sine
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
Performance
Reference
level
standard
B
EN 61000-4-2: 95
A
EN 61000-4-3: 96
ENV 50204: 95
B
EN 61000-4-4: 95
B
EN 61000-4-5: 95
A
EN 61000-4-6: 97
C
EN 61000-4-11: 94
C
C
B
21

Hide quick links:

Advertisement