Tricity Bendix SG210 Operating & Installation Instructions Manual page 24

Gas cooker
Table of Contents

Advertisement

Replace the nozzles of the hob burners
Every appliance has spare nozzles for every
type of gas. The whole length of every nozzle
is marked in millimetres on the nozzle.
Before any modifications or
conversion to a different kind of gas, you
must DISCONNECT the cooker from the
electricity supply and ensure that all
control knobs are in the OFF position, and
the appliance has cooled completely.
Hob burners
Remove the pan support;
Remove the caps and the burner
crowns;
Using a No 7 socket spanner unscrew
the nozzles and replace them with those
required for the type of gas in use (see
table no. 1).
Reassemble the parts following the same
procedure in reverse.
These burners do not need any primary air
regulation.
Adjustment of minimum level for the hob
burners
The burner is correctly adjusted when the
flame is stable silent and goes out without
any noise.
When changing the type of gas check that the
minimum level is correct. The air admission is
correct when the flame is about 4 mm in
length.
The top burners do not need adjustment of
primary air.
Check that, turning the knob quickly from
the maximum position to the minimum
one, the flame does not go out.
To adjust the minimum level:
Light the burner
Turn the knob to the position of the
minimum flame;
Remove the knob;
24
correct
no air
adjustment
excess of
air