Summary of Enhancements
This section highlights the enhancements for AOS A1.04.00.
Added support for 2
Dual FXO/FXS – 1202692G1

Summary of Bug Fixes

This section highlights bug fixes included in AOS version A1.04.00.
With RTP Symmetric Filter enabled, AA audio can't be heard
Issue Detail
When "ip rtp symmetric-filter is enabled, calls to the Auto Attendant can be made, but prompt
audio can't be heard.
Call Appearance can remain in the reserved state
Issue Detail
Call appearances can remain reserved in some instances during transferred calls.
Shared Line Account updates fail
Issue Detail
If IP interfaces configured as Media Gateways use DHCP and the address changes, the
system must restart notifications and subscriptions for SLA notifications. This was not
happening properly.
Overhead Paging output too low
Issue Detail
The output of the paging port was too low to drive some overhead paging systems. The
output level was changed from -3.0 dB to 0 dB.