CHICAGO Welding 45689 Set Up And Operating Instructions Manual page 9

Spot welder
Table of Contents

Advertisement

TONG
TIP
(#48)
To Use The Power Switch:
1.
The Power Switch (part #25) allows electrical current to the Spot Welder to be turned
"ON" and "OFF". (See Figure d, and assy. diagram.)
2.
Turn the Power Switch (part #25) sideways in either direction to start the
current . Release the Power Switch to stop the electrical current.
To Use The Operating Lever:
1.
caution: never touch the upper and lower tongs (parts #46, #47) when
ing a workpiece. Allow the Tong Tips (part #48) and the workpiece to cool before han-
dling. (See Figures a, B, e, and assy. diagram.)
2.
The Operating Lever (part #5) allows you to open and close the Upper and Lower Tongs
(parts #46, #47). (See Figures a, F, and assy. diagram.)
3.
Close the Operating Lever (part #5) during the welding process to compress the work-
pieces between the Tong Tips (part #48). Open the Operating Lever after the spark ap-
pears and each weld is made to release the workpieces. (See
assy. diagram.)
SKU 45689
REAR HEX JAM
NUT (#10)
FRONT HEX JAM
UPPER TONG
(#46)
For technical questions, please call 1-800-444-3353.
OPERATING
LEVER (#5)
NUT (#10)
LOWER TONG (#47)
CAP SCREW
(#3)
HEX NUT (#20)
Figures B, a, F, and
Figure F
electrical
weld-
Page 9