Section 1: Safety Information For Massachusetts Installations: WARNING 1. Installation must be performed by a qualified Disconnect power before installing. Before turning or licensed contractor, plumber or gas fitter power ON, be sure that all controls are in the OFF qualified or licensed by the state, province position.
20,000 BTU/HR Supply Pressure: 11" to 14" W.C. each (27.4 mB to 34.9 mB The total gas consumption of the Thermador Profes- Manifold Pressure: 10" W.C. (24.9 mB) ® sional Indoor Grill with all burners on "HI" is 40,000 BTU/HR.
Important Safety Information CAUTION: The appliance and its individual shut-off valve must be disconnected from the gas supply before any pressure testing of the system at test pressures in excess of 1/2" psig (3.5kPa). CAUTION: The appliance must be isolated from the gas supply system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2"...
Page 5
Section 3: Cabinet Preparation Illustrations Front View Side View Figure 2a must be removable Figure 2b " " Removable Panel " Grease Channel For accessibility to Leveling Leg " grease tray and grease channel, cabinet doors should extend from the Drip Tray bottom of the remov- Support block...
Section 3: Cabinet Preparation Illustrations Professional ® Indoor Grill Model PB30BS Model No. Overall Dimensions Cutout Dimensions PB30BS (199mm) 29- (760mm) 26- (673mm) 13- (338mm) 29- (752mm) 22- (576mm) NOTE: All height width and depth dimensions are shown in inches. All Professional ®...
36" (915 mm) above the grill cooking surface. Table 1 indicates the Thermador hoods, by model See Fig. 3b. Minimum overhang of hood to grill on either number, that are recommended for use with the indoor side is 3 inches (77mm).
Section 6: Unpacking, Moving and Placing the Unit LOCATING YOUR PROFESSIONAL ® GRILL Remove all packing materials and temporary labels from the grill. 1. Check that you have all the items listed for your model, as shown in the chart below. Quantity Item Quantity...
Section 6: Unpacking, Moving and Placing the Unit Natural Gas to Liquid Propane Conversion NOTE: Install the conversion sticker CAUTION (supplied) beside the rating label. (1) When connecting the unit to propane gas, make certain the propane gas tank is equipped with its own high pressure regulator supplied with unit.
Section 7: Gas and Electrical Hook-up With the unit inside of the enclosure, Figure 8 Front - Bottom of Unit, See Detail B, Below complete the connection of the pipe nipple and regulator (see Figure 8 ). Note direction of gas flow as indicated by the arrow on the regulator body.
BURNER AIR ADJUSTMENT FIGURE 9 CAUTION Thermador recommends that burner adjustments be made by a qualified technician at the time of installa- tion. Extreme care should be used when adjustments are made after installation. Improper or lack of adjust- ment may cause harmful by-products and may void your warranty.
Thermador indicating model number. We reserve the right to change specifications or design without notice. Note: These models are not currently certified for use in Canada. Thermador is not responsible for products which are transported from the United States for use in Canada.