Troubleshooting Guide - Vector Power On Board VEC031POB Owner's Manual & Warranty Information

400 watt 800 watt peak
Table of Contents

Advertisement

Television Interference:
The Vector Power-On-Board™ 400 is shielded to minimize interference
with TV signals. However, in some instances, some interference may still
be visible, particularly with weak TV signals. Try the following corrective
measures:
• Position the inverter as far as possible from the television, the antenna
and the antenna cables. Use an extension cable, if necessary
• Adjust the orientation of the inverter, the antenna cables and the TV
power cord to minimize interference
• Make sure that the antenna feeding the television provides an
adequate ("snow free") signal and that high quality, shielded antenna
cable is used
7.

TROUBLESHOOTING GUIDE:

TABLE 1 - INVERTER POWER SWITCH TURNED ON
TROUBLE/ INDICATION
No AC output –
red LED lit
No AC output –
red LED lit
No AC output
No AC output –
Green LED not lit
Low battery alarm
sounds continuously
Low battery
alarm sounds
Motorized power tool
won't start
12
POSSIBLE CAUSE
DC input below 10 Volts
Excessive appliance
load-thermal shutdown
Inverter cold
Inverter fuses open
Bad connection or wiring
Low battery voltage
Excessive start-up load
SUGGESTED REMEDY
Recharge or replace
battery
Reduce load-wait for
inverter to cool. Turn Off,
then turn On
Disconnect load from
inverter. Operate inverter
without load for a few
minutes. Reconnect load.
Open fuse caps in back
of inverter. Remove fuses
and replace with same
type and rating
Tighten all DC
connections
Recharge battery.
Remove load from
inverter while recharging
battery
Rock the On/Off switch
several times. If appliance
does not start, then
appliance will not work
with inverter