Vector VEC024 Owner's Manual & Warranty

Vector VEC024 Owner's Manual & Warranty

400 watt power inverter, 800 watt peak

Advertisement

VEC024
400 WATT
POWER INVERTER
NEW

SOFT START

TECHNOLOGY
800 WATT
PEAK
OWNER'S MANUAL
& WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY,
OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ
AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT
LABELS, PLUS YOUR VEHICLE'S BATTERY MANUFACTURER GUIDELINES. FAILURE TO
DO SO COULD RESULT IN INJURY AND/OR PROPERTY DAMAGE.
4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312
TEL 954-584-4446 • FAX 954-584-5556 • TOLL-FREE 866-584-5504
www.vectormfg.com

Advertisement

Table of Contents
loading

Summary of Contents for Vector VEC024

  • Page 1: Soft Start

    VEC024 400 WATT POWER INVERTER SOFT START TECHNOLOGY 800 WATT PEAK OWNER’S MANUAL & WARRANTY INFORMATION THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BATTERY MANUFACTURER GUIDELINES.
  • Page 2 IMPORTANT SAFETY INSTRUCTIONS To ensure reliable service, your power inverter must be installed and used properly. Please read the installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the WARNING and CAUTION statements in this manual. The CAUTION statements advise against certain conditions and practices that may result in damage to your inverter.
  • Page 3: Table Of Contents

    CONTENTS 1. INTRODUCTION ............4 2. CONTROLS, INDICATORS AND CONNECTORS ....4,5 3. HOW YOUR INVERTER WORKS ..........5 3.1 Principal of Operation ............5 3.2 The MaxxSST 400 Output Waveform ........6 4. INSTALLATION..............6 4.1 Power Source Requirements ..........6,7 4.2 Connection to Power Source..........7,8 4.3 Connection to Load ............8,9 4.4 Placement of Inverter ............9 5.
  • Page 4: Introduction

    INTRODUCTION Your new Vector MAXX 400 SST inverter is one in a series of the mostadvanced DC to AC inverters available today. With proper careandappropriate usage, it will give you years of dependable service in your car, truck, RV or boat.
  • Page 5: How Your Vector Inverter Works

    1. HIGH SPEED COOLING FAN 2. (+) DC POWER CONNECTION 3. (–) DC POWER CONNECTION HOW YOUR VECTOR INVERTER WORKS The inverter converts low voltage DC (direct current) from a battery or other power source to standard 110 volt AC (alternating current) household power.
  • Page 6: The Maxxsst 400 Output Waveform

    3.2 THE MAXX SST 400 WATT OUTPUT WAVEFORM The AC output waveform of the MAXX 400 SST is known as “modified sine wave”. It is a waveform that has characteristics similar to the sine wave shape of utility power. This type of waveform is suitable for most AC loads, including linear and switching power supplies used in electronic equipment, transformers, and motors.
  • Page 7: Connection To Power Source

    Example: If a load is rated at 400 watts AC, the power source must be able to deliver: 400 divided by 10 = 40 amperes CAUTION: The MAXX 400 SST must be connected only to batteries with a nominal output voltage of 12 volts. The unit will not operate from a 6 volt battery and will sustain permanent damage if connected to a 24 volt battery.
  • Page 8 Connect the red cable to the red post marked “(+)” on the back of the inverter. Connect the battery clip to the positive terminal of the battery. Check to be sure that all connections between battery clips and terminals are secure. Direct Hardwiring to Power Source: Use #10 AWG wire if the inverter to power source connection is 12 feet or less.
  • Page 9: Connection To Load

    4.3 CONNECTION TO LOAD The MAXX 400 SST is equipped with dual standard North American AC power receptacles. Plug the cord from the equipment you wish to operate into the AC receptacle(s). The green LED indicator lights to indicate that the inverter is functioning.
  • Page 10: Operating Tips

    BATTERY OPERATING TIME With a typical vehicle battery, a minimum operating time of 2 to 3 hours can be expected. In most instances, 5 to 10 hours of operating time is achievable. However, Vector recommends that the operator start the vehicle...
  • Page 11: Protective Features Of Inverter

    every 2 to 3 hours to recharge the battery system. This will guard against any unexpected shut-down of the equipment and will ensure that there is always sufficient battery capacity to start the vehicle’s engine. The inverter will sound it’s alarm when DC voltage drops to 10.6 volt. The inverter may be used whether or not the vehicle’s engine is running.
  • Page 12: Common Problems

    TELEVISION INTERFERENCE: The Vector MAXX 400 SST is shielded to minimize interference with TV signals. However, in some instances, some interference may still be visible, particularly with weak TV signals. Try the following corrective measures: •...
  • Page 13: Troubleshooting

    TROUBLESHOOTING GUIDE: TABLE 1 - INVERTER POWER SWITCH TURNED ON TROUBLE/ INDICATION POSSIBLE CAUSE SUGGESTED REMEDY No AC output – DC input below 10 volts Recharge or replace red LED lit battery No AC output – Excessive appliance Reduce load-wait for red LED lit load-thermal shutdown inverter to cool.
  • Page 14: Fuse Replacement

    If the unit is damaged during fuse replacement, the warranty may be voided. Vector recommends contacting Vector Technical Support for guidance. Based on experience, it is best to return the unit to Vector for repair. Vector Technical Support can be reached by calling toll free 866-584-5504.
  • Page 15 Vector Manufacturing. Any defective product, other than accessories, that is returned to Vector Manufacturing within 30 days of the date of purchase may be replaced free of charge . If such a product is returned more than 30 days but less than two years from the purchase date, Vector Manufacturing will repair the unit or, at its option, replace it free of charge.
  • Page 16 © 2004 VECTOR MANUFACTURING, Ltd. FT. LAUDERDALE, FL 33312 MADE IN CHINA VECTOR MANUFACTURING, LTD...

This manual is also suitable for:

Maxx sst vec024