Mitsubishi Electric Mr.SLIM PKA-A12GA Service Manual page 17

Split-type, heat pump air conditioners split-type, air conditioners
Table of Contents

Advertisement

PKA-A24FA PKA-A30FA PKA-A36FA
PKA-A24FA
PKA-A30FA
1
[LEGEND]
SYMBOL
NAME
P.B
INDOOR POWER BOARD
I.B
INDOOR CONTROLLER BOARD
FUSE
FUSE (6.3A/250V)
ZNR
VARISTOR
CN2L
CONNECTOR<LOSSNAY>
CN32
CONNECTOR<REMOTE SWITCH>
CN41
CONNECTOR<HA TERMINAL-A>
CN51
CONNECTOR<CENTRALLY CONTROL>
SW1
SWITCH <MODEL SELECTION> See Table 1.
SW2
SWITCH <CAPACITY CODE> See Table 2.
SWE
SWITCH<EMERGENCY OPERATION>
X4
RELAY<FAN MOTOR>
BCR
FAN CONTROL ELEMENT
LED1
POWER SUPPLY<I.B>
LED2
POWER SUPPLY<R.B>
LED3
TRANSMISSION<INDOOR-OUTDOOR>
P.B
CNDK
CN2S
(RED)
(WHT)
1
1
2
2
DC13.1V
3
MF
1
2 3
C
I.B
POWER
1 3 5
1 3
FAN
CNDK
( WHT )
(RED)
X4
BCR
X4
LED3 LED2 LED1
SW2 SW1
SWE
ON
OFF
Refer to tables 1 and 2
for service PCB.
Table 1
Table 2
SW1
Service board
MODELS
1 2 3 4 5
PKA-
ON
A24FA(L)
OFF
NOTES:
1. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
2. Indoor and outdoor connecting wires have polarities, make sure to match terminal numbers (S1, S2, S3) for correct wiring.
3. Symbols used in wiring diagram above are,
4. This diagram shows the wiring of Indoor and Outdoor connecting wires (specification of 230V), adopting superimposed system of
power and signal.
1. Use copper supply wires.
PKA-A36FA
1
1
SYMBOL
C
CAPACITOR<FAN MOTOR>
FAN MOTOR
MF
MV
VANE MOTOR
TB4
TERMINAL BLOCK<INDOOR/OUTDOOR
CONNECTING LINE>
TB5,TB6
TERMINAL BLOCK<REMOTE CONTROLLER
TRANSMISSION LINE>
TH1
ROOM TEMP.THERMISTOR
°
°
<32
F/15kΩ, 77
F/5.2kΩ DETECT>
TH2
PIPE TEMP.THERMISTOR/LIQUID
°
°
<32
F/15kΩ, 77
F/5.2kΩ DETECT>
TH5
COND./EVA.TEMP.THERMISTOR
°
°
<32
F/15kΩ, 77
F/5.2kΩ DETECT>
R.B
WIRED REMOTE CONTROLLER BOARD
Please set the voltage
using the remote controller.
For the setting method,
please refer to the indoor
unit Installation Manual.
YLW
ORN
YLW
ORN
BRN
POWER
1 3
1 2
1 3
CND
(ORN)
POWER
A-CONTROL
CN2D(WHT)
CN3C(BLU)
CN41
CN2L
ZNR
CN51
CN32
INTAKE
LIQUID
PIPE
REMOCON
CN21
CN20
CN29
CN22
( RED )
( WHT )
( BLK )
( BLU )
1 2
1 2
1 2
1 2
TH2
TH1
TH5
SW2
Service board
Service board
MODELS
1 2 3 4 5
1 2 3 4 5
PKA-
ON
A30FA(L)
OFF
: Connector,
: Terminal (block).
PKA-A24FAL
PKA-A30FAL PKA-A36FAL
PKA-A24FAL
PKA-A30FAL
1
NAME
SYMBOL
W.B
WIRELESS REMOTE CONTROLLER BOARD
RU
RECEIVING UNIT
BZ
BUZZER
LED1
LED<RUN INDICATOR>
LED2
LED<HOT ADJUST>
SW1
SWITCH<HEATING ON/OFF>
SW2
SWITCH<COOLING ON/OFF>
TB4
1
S1
TO
S2
OUTDOOR
UNIT
S3
VANE
6
CN6V
( GRN )
MV
WIRELESS
CN90
( WHT )
9
RECEIVER
2
1
TRANSMISSION WIRES DC12V
TB5
Service board
MODELS
1 2 3 4 5
PKA-
ON
ON
A36FA(L)
OFF
OFF
17
PKA-A36FAL
1
NAME
For A24/30/36FAL
CNB
BZ
RU
LED1 LED2 SW2 SW1
W.B
R.B
1
TB6
2
For A24/30/36FA
1