Planning Information
Model CT30G 30"
(762)
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, cut-out dimensions and
installation specifics.
Wolf recommends using 33" (838) wide
cabinets with the 30" (762) cooktop.
A Wolf downdraft system, Cooktop or Pro
ventilation hood is recommended. When
installing a ventilation hood, refer to the specific
requirements of the hood for the minimum
dimension to the countertop. Also refer to
Ventilation Recommendations in the Cooktop
Ventilation or Pro Ventilation sections of our
website, wolfappliance.com.
The Wolf 30" (762) gas cooktop requires a
separate 120 V AC, 60 Hz power supply. The
service should have its own 15 amp circuit
breaker and a grounded 3-prong receptacle
should be located within the reach of the
6' (1.8 m) power cord. Locate electrical within
the shaded area shown in the Installation
Specifications illustration on page 4.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
When a gas cooktop is installed above
cabinets, the gas and electrical placement is not
critical. A grounded outlet needs to be placed
within 4' (1.2 m) of the right rear of the
cooktop.
A Wolf 30" (762) built-in single oven may be
installed below this cooktop. For this installa-
tion, the electrical and gas supply for the
cooktop should be installed in the adjacent
cabinet. Refer to page 6 for additional specifica-
tions. Be aware of the depth of the cooktop
when planning for this installation.
IMPORTANT NOTE: Wolf gas cooktops are
designed and agency approved for installation
with Wolf built-in ovens only.
Dimensions in parentheses are in
millimeters unless otherwise specified.
Gas Cooktop
IMPORTANT NOTE: When a oven is installed
below the cooktop, unless you are using
cabinets deeper than 24" (610), it is recom-
mended that the electrical supply for the oven
be placed in an adjacent cabinet within reach of
the conduit. A 2" (51) diameter hole to route the
conduit through cabinetry will be required. Refer
to page 6 for location of electrical supply and
additional specifications.
on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP (propane) gas at 10" (25
mb) WC pressure. The minimum line pressure
for natural gas is 7" (17.5 mb) WC and 11"
(27.4 mb) WC for LP gas. The maximum gas
supply pressure to the regulator should never
exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa). The
cooktops are supplied with a
connection at the right rear bottom corner of
the cooktop. The male connector exits the unit
straight down and you are supplied with a
regulator with two female connectors.
function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas installa-
tions from 8,000' (2438 m) to 10,000' (3048 m)
need the high altitude conversion kit. LP gas
installations will operate up to 10,000' (3048 m)
without adjustment.
and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.
side by side, refer to the countertop cut-out
dimensions on page 7.
shipped with each Wolf product for detailed
specifications.
Wolf gas cooktops are designed to operate
Wolf gas cooktops using natural gas
You must follow all National Electrical Code
When multiple cooktop units are installed
Refer to the installation instructions
This cooktop is intended for indoor use only.