Filtration Process; Led Display; Operation; Starting The System - Antunes Filtration Technologies UFL-420 9700464 Owner's Manual

Ufl-420/440 series water filtration system
Table of Contents

Advertisement

UFL-420/440 WATER FILTRATION SYSTEM

Filtration Process

Water filtration in the UFL Series is accomplished using
two modes:
• Flush Interval ( on the LED display)
• Flush Duration ( on LED display).
During the Flush Interval mode, water enters the inlet
and flows through the filter element before exiting the
Permeate outlet as usable product water. After a cer-
tain period of time, depending upon water quality, the
filter has to be cleaned. This is accomplished through
the Flush Duration Mode. During this mode, the drain
valve opens and flushes the membrane to remove
debris collected inside the membrane walls.
NOTE: Both the Flush Interval Mode and the Flush
Duration Mode can be automated by programming
the timer. During the Flush Interval Mode, the valve
is not powered in order to keep water filtering during
a power outage.

LED Display

 - Flush Interval Mode is the time between flushings
and is displayed in minutes or hours.
 - Flush Duration Mode is the amount of time used
to flush and remove debris from filter cartridge and
is displayed in seconds.
 - Manual Flush Mode operation, solenoid is
manually activated by the user.

OPERATION

Starting the System

Power up the unit.
The LED read-out displays the following for about two
seconds each:
1. 
2.  followed by its time settings in seconds.
3.  and its time setting, in minutes or hours.
The  and  sequence repeats for 30 seconds
after which, the unit automatically returns to the
Flush Interval Mode (). The time setting for 
will be displayed and the decimal point will flash in
one second intervals.
NOTE: The timer can be programmed immediately
after start-up or while in Flush Interval Mode.