Attach The Belt Cap Retainer; Installation; Installation Safety Instructions - Chamberlain 3280 Owner's Manual

Hide thumbs Also See for 3280:
Table of Contents

Advertisement

ASSEMBLY STEP 3

Attach the Belt Cap Retainer

• Position the belt cap retainer over the motor unit
sprocket so the two holes in cap align with the two
holes in mounting plate. Attach with 8x3/8" hex
screws provided.
You have now finished assembling your garage
door opener. Please read the following warnings
before proceeding to the installation section.
HARDWARE SHOWN
ACTUAL SIZE

INSTALLATION

IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS
AND INSTRUCTIONS.
2. Install garage door opener only on properly balanced
and lubricated garage door. An improperly balanced
door may not reverse when required and could result in
SEVERE INJURY or DEATH.
3. All repairs to cables, spring assemblies and other
hardware MUST be made by a trained door systems
technician BEFORE installing opener.
4. Disable all locks and remove all ropes connected to
garage door BEFORE installing opener to avoid
entanglement.
5. Install garage door opener 7 feet (2.13 m) or more
above floor.
6. Mount emergency release handle 6 feet (1.83 m) above
floor.
7. NEVER connect garage door opener to power source
until instructed to do so.
Hex Screw
#8x3/8"
To avoid possible SERIOUS INJURY to fingers from
moving garage door opener:
• ALWAYS keep hand clear of sprocket while operating
opener.
• Securely attach sprocket cover before operating.
Hex Screws 8x3/8"
WARNING
WARNING
WARNING
8. NEVER wear watches, rings or loose clothing while
installing or servicing opener. They could be caught in
garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of 5 feet
(1.5 m).
• away from all moving parts of the door.
10. Place entrapment warning label on wall next to garage
door control.
11. Place manual release/safety reverse test label in plain
view on inside of garage door.
12. Upon completion of installation, test safety reversal
system. Door MUST reverse on contact with a
1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on
the floor.
7
WARNING
CAUTION
Belt Cap
Retainer
Motor Unit
Sprocket