INSTALLATION INSTRUCTIONS FOR BLOWER KIT,
mODEL ADAGIO-BLWR (CAT. NO. H66) FOR USE WITH
ADAGIO
-mN & ADAGIO-mP DIRECT-VENT GAS
FIREPLACE HEATERS
KIT CONTENTS:
1 ea. Blower
1 ea. Instruction Sheet
2 ea. Blower Mounting
Screws
2 ea. Wire Clips
TOOLS / SUPPLIES NEEDED
3/8" Nut Driver
3/4" Wrench
GENERAL INFORmATION
ImPORTANT NOTE: This Forced Air Blower Kit can be use on
millivolt models only.
The main power supply must be wired to the J-box/receptacle and wall
switch at the time the fireplace was installed (if not, then this kit cannot
be installed).
• All electrical wiring must be performed by licensed
Electricians. Electrical wiring must comply with
the National Electrical Code ANSI/ NFPA 70 -
latest edition, in Canada, the current CSA C22-
Canadian Electrical Code.
• main power must be off when connecting to main
electrical power supply or performing service .
• The Ground Lead must be connected to the green
screw (located on the junction box). Failure to do
this could result in an electrical short or shock
injury.
• The appliance must be electrically grounded in
accordance with local codes or, in the absence of
local codes, the national electrical code, ANSI/
NFPA 70-(latest edition), in Canada, the current
CSA C22- Canadian Electrical Code.
• Leather gloves should be worn during installation
to prevent injury or cuts to the hands!
ImPORTANT
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
750,238m
REV. NC, 08/2007
ALL WARNINGS, PRECAUTIONS AND INSTRUCTIONS PROVIDED IN THE
INSTALLATION AND OPERATION mANUAL PROVIDED WITH THE APPLIANCE
APPLY TO THESE INSTRUCTIONS. THOROUGHLY READ AND FOLLOW THE
INSTRUCTIONS PROVIDED WITH THE APPLIANCE BEFORE PROCEEDING TO
THE FOLLOWING INSTRUCTIONS.
INSTALLATION INSTRUCTIONS
Step . For your safety, turn off the fireplace and allow it to cool before
proceeding.
Step 2. If the appliance is connected to 120 volt power, disconnect the
power by turning off the circuit breaker.
Step 3. Shut off the gas supply to the fireplace.
Step 4. Remove the façade if installed.
Step 5. Remove the existing on/off switch (for burner) and bracket in the
control compartment per the instructions in Figure 1. Do not
remove the On/Off switch or Piezo from the bracket.
Step 6. Remove Gas Line to allow for easier access to blower mounting
location. See Figure 3
Figure 1 - Remove Switch and Piezo Bracket as shown by pulling
the assembly toward you (no tools required)
HEARTH PRODUCTS
KITS AND ACCESSORIES
mODEL ADAGIO-BLWR BLOWER KIT
TM


Advertisement

loading

Summary of Contents for Lennox H6161

  • Page 1 HEARTH PRODUCTS KITS AND ACCESSORIES 750,238m mODEL ADAGIO-BLWR BLOWER KIT REV. NC, 08/2007 INSTALLATION INSTRUCTIONS FOR BLOWER KIT, mODEL ADAGIO-BLWR (CAT. NO. H66) FOR USE WITH ADAGIO -mN & ADAGIO-mP DIRECT-VENT GAS ™ FIREPLACE HEATERS ALL WARNINGS, PRECAUTIONS AND INSTRUCTIONS PROVIDED IN THE KIT CONTENTS: INSTALLATION AND OPERATION mANUAL PROVIDED WITH THE APPLIANCE APPLY TO THESE INSTRUCTIONS.
  • Page 2 Figure 2 - Mounting Screw Locations Figure 4 - Blower Wiring Diagram BLOWER JUNCTION NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Printed in U.S.A. © 2007 by Lennox Hearth Products P/N 750,238m REV. NC 08/2007 0 West Taft Avenue • Orange, CA 92865...

This manual is also suitable for:

Adagio-blwr h6161