This dryer is supplied without an electric cord and plug. It must
be connected by a competent
electrician to a single-phase
electricity supply at the voltage shown on the dataplate, using a
suitable fixed wiring installation in accordance with local and
national wiring regulations.
[]
A 3-wire circular cord of minimum conconductor
size 2.5 mm2
cross-section
area should be used.
[]
A 30A supply fuse should be used, and a switch having
a contact separation in both poles that provides full
disconnection
under over-voltage category Ill conditions
must be incorporated into the fixed wiring in accordance with
local wiring regulations. The dryer should be positioned so
that the disconnection
switch is easily accessible to the user.
[]
A cord clamp bush is provided on the dryer, and should be
tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made in
accordance with the terminal markings. Remember to replace
the terminal access panel (terminal block cover).
NOTE: In accordance
with the European EMC Directive
(2004/108/EC),
the maximum electricity
supply system
impedance to which the electric dryer should be connected
is declared to be 0.29 Ohm + j0.18 Ohm.
Electric
Shock Hazard
This is a 3=wire appliance
which must be earthed.
Do not earth to a gas pipe.
Failure to follow these instructions could result in
death, fire, or serious injury.
203 mm
(8")
921 mm
(36i/4")
25 mm
(1")
736 mm
,
(29)
695 mm
(27114,,)
/
1
SIDE VlEW
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond path is adequate.
AUSTRALIA ONLY
For Australia, each single electric dryer is fitted with a cord
and plug, with conductors
of 2.5 mm2 cross sectional area,
and should be plugged into a suitable electrical socket at the
voltage shown on the dataptate.
Do not use extension lead
assemblies on commercial
installations.
If the supply cord is
damaged, it must be replaced with a specially terminated cord
by an authorized service agent or a similarly qualified person in
order to avoid a hazard. Each electric dryer for other countries
is supplied without an electric cord and plug.
Recommended
Earthing
Method
[]
It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance
with all local codes and ordinances.