KitchenAid KECD807XBL01 Installation Instructions Manual

KitchenAid KECD807XBL01 Installation Instructions Manual

30" and 36" electric downdraft cooktop
Hide thumbs Also See for KECD807XBL01:
Table of Contents

Advertisement

Available languages

Available languages

30" (76.2 CM) AND 36" (91.4 CM) ELECTRIC
DOWNDRAFT COOKTOP
INSTALLATIONINSTRUCTIONS
INSTRUCTIONS D'INSTALLATION DE LA TABLEDE
CUISSON ELECTRIQUEAVEC ASPIRATION
PARLEBAS DE 30" (76,2 CM) ET36" (91,4 CM)
Table of Contents/Table des mati_res
COOKTOP SAFETY ........................................................................
2
INSTALLATION REQUIREMENTS ................................................
2
Tools and Parts ............................................................................
2
Location Requirements ................................................................
3
Venting Requirements ..................................................................
4
Venting Methods ..........................................................................
5
Electrical Requirements ...............................................................
7
INSTALLATION INSTRUCTIONS ..................................................
7
Prepare Cooktop ..........................................................................
7
Install Foam Strip .........................................................................
8
Rotate Blower - Optional .............................................................
8
Install Cooktop .............................................................................
8
Make Electrical Connection .........................................................
9
Complete Installation .................................................................
10
SECURITE DE LA TABLE DE CUlSSON .................................... 11
EXIGENCES D'INSTALLATION ...................................................
11
Outils et pieces ...........................................................................
11
Exigences d'emplacement .........................................................
12
Exigences concernant I'evacuation ........................................... 14
Methodes d'evacuation ..............................................................
15
Specifications electriques ..........................................................
16
............................................ 17
Preparation de la table de cuisson ............................................ 17
Installation de la bande de mousse ........................................... 17
Installation de la table de cuisson ..............................................
18
Raccordement electrique ...........................................................
19
Achever I'installation ..................................................................
20
iMPORTANT:
Save for local electrical inspector's use.
iMPORTANT:
,&, c onserver pour consultation par I'inspecteur local des installations 61ectriques.
W10439665A

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid KECD807XBL01

  • Page 1: Table Of Contents

    30" (76.2 CM) AND 36" (91.4 CM) ELECTRIC DOWNDRAFT COOKTOP INSTALLATIONINSTRUCTIONS INSTRUCTIONS D'INSTALLATION DE LA TABLEDE CUISSON ELECTRIQUEAVEC ASPIRATION PARLEBAS DE 30" (76,2 CM) ET36" (91,4 CM) Table of Contents/Table des mati_res COOKTOP SAFETY ................ SECURITE DE LA TABLE DE CUlSSON ........11 INSTALLATION REQUIREMENTS ..........
  • Page 2: Cooktop Safety

    COOKTOP SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER"...
  • Page 3: Location Requirements

    s}c<x o ' s:ents IMPORTANT: Observe all governing codes and ordinances. 36" (91.4 cm) Cooktop - for standard and electric models When installing cooktop, use minimum dimensions given. • To eliminate the risk of burns or fire by reaching over the heated surface units, cabinet storage space located above the surface units should be avoided.
  • Page 4: Venting Requirements

    Cutout Dimensions Cabinet Dimensions A. 28%" (73.4 cm) maximum on 30" (76.2 cm) models 349/16 '' (87.8 cm) maximum on 36" (91.4 cm) models B. 21%" (53.7 cm) maximum on both 30" (76.2 cm) and 36" (91.4 cm) models C. 81%='' (21.8 cm) on 30" (76.2 cm) models 157/16 '' (39.2 cm) on 36"...
  • Page 5: Venting Methods

    For Best Performance: • Use 26-gauge minimum galvanized or 25-gauge minimum aluminum metal vent. Poor quality pipe fittings can reduce Common venting methods are shown for a counter-mounted airflow. Flexible metal vent is not recommended. downdraft cooktop. The cooktop may be vented through the wall or floor.
  • Page 6 Concrete Slab Installations - Exhaust Through Wall 6" (15.2 cm) to 31/4"x 10" 1 ft (8.3 cm x 25.4 cm) transition (0.3 m) 31/4"x 10" (8.3 cm x 25.4 cm) 9.0 ft to 6" (15.2 cm) 90 ° elbow (2.7 m) transition 6"...
  • Page 7: Electrical Requirements

    Before You Make the Electrical Connection: To properly install your cooktop, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. • A 4-wire or 3-wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply on a separate, 40-amp circuit breaker is required for both 30"...
  • Page 8: Install Foam Strip

    4. Remove the removable grease filter by lifting the filter out. To rotate blower: 5. Using 2 or more people, remove the cooktop from the carton. 1. Locate the four plastic plugs in the plenum bypass. 6. Use foam end caps from the packaging as a work surface for 2.
  • Page 9: Make Electrical Connection

    4-Wire Cable from Home Power Supply to 4-Wire Cable from Cooktop IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction, and in Canada.
  • Page 10: Complete Installation

    3-Wire Cable from Home Power Supply to 4-Wire Cable _o_l_©/_ IDc_ ¸ /_ ._/_ o from Cooktop - U.S. only 1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped. IMPORTANT: Use the 3-wire cable from power supply where local codes permit connecting the frame-ground conductor...
  • Page 11: Securite De La Tabledeculsson

    SECURITE DE LA TABLEDECUlSSON Votre securite et celle des autres est tres importante. Nous donnons de nombreux messages de s6curit6 importants dans ce manuel et sur votre appareil m6nager. Assurez-vous toujours lire tousles messages de s6curit6 et de vous y conformer. Ce symbole d'alerte de s6curit6 vous signale les dangers potentiels de d6ces et de blessures graves &...
  • Page 12: Exigences D'emplacement

    IMPORTANT : Observer les dispositions de tous les codes et Table de cuisson de 36" (91,4 cm) - Pour les modules standard et _lectriques r_glements en vigueur. Lors de I'installation de la table de cuisson, utiliser les dimensions minimales indiqu6es. •...
  • Page 13 Dimensions du placard Dimensions de I'ouverture _ d_couper A. 28 _" (73,4 cm) maximum sur les modeles de 30" (76,2 cm) 34_" (87,8 cm) maximum sur les modeles de 36" (91,4 cm) B. 21 _" (53, 7 em) maximum sur les modeles de 30" (76,2 cm) et de 36"...
  • Page 14: Exigences Concernant I'evacuation

    IMPORTANT : L'evacuation de cette table de cuisson doit se • Ne pas installer 2 coudes ensemble. faire & I'exterieur. • Ne pas utiliser plus de trois coudes a 90 °. • Ne pas terminer le circuit d'evacuation clans un grenier ou •...
  • Page 15: Methodes D'evacuation

    Lesmethodes d'evacuation standard i llustrees correspondent & Installations dans dalle de b_ton - I_vacuation _ travers un une table de cuisson avec aspiration par le bas montee puits de fen6tre comptoir. L'evacuation de la table de cuisson peut se faire par le mur ou le plancher.
  • Page 16: Specifications Electriques

    Exemple de circuit d'_vacuation Calcul de la Iongueur effective du circuit d'_vacuation bouche de d_charge murale Pour calculer la Iongueur effective du circuit d'evacuation 6pi(1,Sm) necessaire, additionner les Iongueurs equivalentes (pieds/metres) oo°°o °0° de tousles composants utilises dans le systeme. Composant Conduit de diam_tre...
  • Page 17: Instructions D'installation

    Avant d'_tablir la connexion _lectrique Pour installer la table de cuisson correctement, il faut etablir le • Un connecteur de conduit homologue UL ou CSA dolt _tre type de raccords electriques que I'on utilisera et suivre les fourni & chaque extremite du c&ble d'alimentation electrique instructions indiqu6es ici.
  • Page 18: Rotation Du Ventilateur-Facultative

    3. Inserer la cle & douille de 3/8"et la rallonge dans le trou et devisser I'ecrou d'un demi-tour & I'aide de la poignee & cliquet. Repeter cette operation pour chacun des quatre IMPORTANT : Les etapes supplementaires suivantes doivent ecrous. _tre execut6es si le produit est installe clans une configuration 4.
  • Page 19: Raccordement Electrique

    C&ble _ 4 conducteurs depuis le point de distribution du domicile jusqu'au c&ble _ 4 conducteurs de la table de cuisson IMPORTANT : Utiliser le c&ble a 4 conducteurs provenant du point de distribution du domicile aux 12tats-Unis Iorsque les codes ne permettent pas la mise a la terre par I'intermediaire conducteur neutre, en cas de nouvelle installation avec...
  • Page 20: Achever I'installation

    C&ble & 3 conducteurs depuis le point de distribution du Ach®v®/ c£on domicile jusqu'au c&ble & 4 conducteurs de la table de 1. Verifier que toutes les pieces sont maintenant installees. S'il cuisson - E.-U. seulement reste une piece, passer en revue les differentes etapes pour decouvrir laquelle aurait et6 oubliee.

This manual is also suitable for:

Kecd807xss01Kecd867xbl02Kecd867xss02

Table of Contents