14 en | Installation
4.3

Cable requirements

4.3.1

Video transmission (coaxial)

Cable type
runs < 300m (1000 ft)
runs < 600m (2000 ft)
Cable diameter (outer)
Cable shape
Cable shield
Center conductor
DC resistance
RG-59/U
RG-11/U
Cable impedance
Certificating authority
Environmental
Temperature rating
Reference type
Table 4.2 Video cable specifications
4.3.2

Input power cord

Cable type
Cable diameter (outer)
Cable shape
Conductors
Voltage rating
Certificating authority
Environmental
Temperature rating
Reference type
Table 4.3 Power cord specifications for North America
F.01U.026937 | V 2.0 | 2007.01
RG-59/U
RG-11/U
4.6 mm to 7.9 mm
(0.18 in to 0.31 in)
Round
>93% braided copper
Stranded or solid copper
<15 ohm/1000 m
<6 ohm/1000 m
75 ohm
UL
Outdoor rated
+80 °C (+176 °F) or greater
Belden 9259
3 x 18 AWG
4.6 to 7.9 mm
(0.18 to 0.31 in)
Round
3 or 2
300 V
UL/C.S.A., UL VW-1
Outdoor rated
+105° C (+221° F) or greater
Belden 19509, 3-conductor;
Northwire FSJT183-81K, 3-conduc-
tor