Gas supply requirements
Explosion Hazard
Use a new AGA or CSA approved
gas
supply
line,
Install a shutoff valve.
Securely
tighten
all gas connections.
If connected
to LP, have a qualified
person
make
sure gas pressure
does
not exceed
14" (35.6 cm) water
column,
Examples
of a qualified
person
include:
licensed
heating
personnel,
authorized
gas company
personnel,
and
authorized
service
personnel.
Failure
to do so can
result
in death,
explosion,
or fire.
In the State
of Massachusetts,
the
following
installation
instructions
apply:
• Installations
and repairs
must
be
performed
by a qualified
or licensed
contractor,
plumber,
or gasfitter
qualified
or licensed
by the State
of Massachusetts.
. If using
a ball valve,
it shall
be a
T-handle
type.
. A flexible
gas connector,
when
used,
must
not exceed
3 feet.
Observe all governing
codes and
ordinances.
This
installation
must
conform
with
local
codes
and ordinances.
In the absence
of
local
codes,
installations
must
conform
with
American
National
Standard,
National
Fuel
Gas Code ANSI
Z223.1
--
latest
edition*,
or CAN/CSA-B149
--
latest
edition*,
institution
codes.
Input
ratings
shown
on the
model/serial
rating
plate
are for
elevations
up to 2,000
feet (610 m). For assistance
when
installing
the range
at higher
elevations,
contact
your
local
service
company.
Type
of gas:
This
range
is design-
certified
by CSA
International
for use
with
Natural
gas or, after
proper
conversion,
for use with
LR gas.
This
range
is factory
set for
use with
Natural
gas.
Gas conversion
instructions
are
provided
in "Gas
conversions"
section.
The model/serial
rating
plate
located
on
the frame
behind
the storage
drawer
or
broiler
door
has information
on the type
of gas that
can be used.
If the type
of
gas listed
does
not agree
with
the type
of
gas available,
check with
the local
gas
supplier.
Conversion
must
be done
bya
qualified
service
technician.
Gas supply
line:
Provide
a gas supply
line of 3/4"
rigid
pipe to the
range
location.
With
LR gas,
piping
or tubing
size can
be 1/2" minimum.
A smaller
size
pipe
on longer
runs
may
result
in
insufficient
gas supply.
Usually,
LR gas
suppliers
determine
the size and
materials
used
in the system.
Pipe-joint
compounds
made
for use with
L.R gas must
be used
on pipe threads
only.
Flexible
metal
appliance
connector:
If
local
codes
permit,
a new AGA
or CSA
design-certified,
1/2" or 3/4" I.D., flexible
metal
appliance
connector
is
recommended
for
connecting
range
to
the gas supply
line. A 1/2" male
pipe
thread
nipple
is needed
for connection
to
pressure
regulator
female
pipe
threads.
Do not kink or damage
the flexible
metal
tubing
when
moving
the range.
Rioidpipe
connection:
Requires
a
combination
of
pipe
fittings
to
obtain
an in-line
connection
to the range.
All strains
must
be removed
from
the
supply
and fuel
lines
so range
will
be
level
and in line.
Shutoff
valve:The
supply line must be
equipped
with a manual shutoff
valve.
This valve should
be located in the same
room as the range and should
be in a
location
that allows ease of opening
and
closing.The
valve is for turning
on or
shutting
off gas to the range. Do not
block access to shutoff valve.
manual
shutoff
valve
"open"
position
to
ige
gas supply
Pressure
regulator:The
gas pressure
regulator
supplied
with
this
range
must
be used.The
inlet
pressure
to the
regulator
should
be as follows
for proper
operation:
NATURAL
GAS:
Minimum
pressure:
5 inchesW.C.
Maximum
pressure:
14 inches W.C.
L.R GAS:
Minimum
pressure:
11 inchesW.C.
Maximum
pressure:
14 inches W.C.
Contact
local
gas supplier
if you
are not
sure
about
the inlet pressure.
Line
pressure
testing
above
1/2 psi gauge
(14" WCP) --The
range
and its individual
manual
shutoff
valve
must
be
disconnected
from
the gas supply
piping
system
during
any pressure
testing
of
that system
at test
pressures
greater
than
1/2 psig (3.5 kPa).
Line
pressure
testing
at 1/2 psi gauge
(14" WCP) or lower--The
range
must
be
isolated
from
the gas supply
piping
system
by closing
its individual
manual
shutoff
valve
during
any
pressure
testing
of that system
at test
pressures
equal
to
or less than
1/2 psig
(3.5 kPa).