Download Print this page

Whirlpool SF395LEEQ0 Installation Instructions Manual

30" freestanding sealed burner gas range with self-cleaning oven

Advertisement

Quick Links

WARNING
• ALL RANGES CAN
TIP
• INJURY TO PERSONS
COULD RESULT
• INSTALL ANTI-TIP
DEVICE
PACKED
WITH RANGE
• SEE INSTALLATION
INSTRUCTIONS
Quick Reference
Table of Contents:
Pages
[]
[]
[]
[]
%-%
r Back cover 1
I
Back
cover !
I Back c ovar]
Before you start
Product dimensions
Cabinet dimensions/requirements
Electrical requirements
Gas supply requirements
Installation steps
Gas conversions
If range does not operate
If you need assistance/service
Moving the range
If you need assistance:
Check your Use and Care Guide for a toll-free number to call or call
the dealer from whom you purchased this range. The dealer is listed
in the Yellow Pages of your phone directory under "Appliances-
Household -- Major -- Service and Repair."
Call when you:
Have questions about range installation or operation.
[]
Need to obtain the name and number of an authorized
servme company.
When you call, you will need:
[] The range model number.
[] The range serial number.
Both numbers are listed on the model/serial rating plate located on
the frame behind the storage drawer.

Advertisement

loading

Summary of Contents for Whirlpool SF395LEEQ0

  • Page 1 Quick Reference Table of Contents: Pages Before you start Product dimensions Cabinet dimensions/requirements Electrical requirements Gas supply requirements Installation steps Gas conversions r Back cover 1 If range does not operate If you need assistance/service cover ! Back I Back c ovar] Moving the range If you need assistance: Check your Use and Care Guide for a toll-free number to call or call...
  • Page 2 Important: Observe all governing codes and ordinances. This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 -- latest edition**. Proper installation is your responsibility. A qualified technician must install this range.
  • Page 3 Electronic ignition systems operate within wide level _._1 voltage limits, but proper grounding and polarity are necessary•In addition to checking that the outlet is correctly grounded, the outlet must be 1/8" drive checked by a qualified electrician to see if it is "...
  • Page 4 Check cooktop burners for proper flame Plug power supply cord into grounded outlet Check broiler burner for proper flame i Make proper gas connection Chock oven burner for proper flame Install anti, tip bracket Secure range with anti-tip bracket ! Level range Replace storage drawer Preparation...
  • Page 5 Before moving range across floor, checkthat Operating position range is still on cardboard shipping base to protect floor covering. front levelingleg = Carefully move range into final operating position. Check that Place rack in oven, Place level on rack, rear leveling leg is first side to side;...
  • Page 6 Check operation mirror Electronic ignition system Cooktop and oven burners use electronic ignitors in place of standing pilots. When a cooktop control knob is turned to the "LIGHT" flame_ spreader position, the system creates a spark to light the burner. This sparking continues until the refle_ion control knob is turned to the desired setting.
  • Page 7 Check operation (cont.) = =_:I:1 C.LO_ ooo_ g_,lcE _ • START _ -- CLE_N and screw If flame needs to be adjusted: Loosen the lock screw on the air shutter located at the rear of the broil burner. Adjust the air shutter as needed. 1.
  • Page 8 Natural gas conversion Remove and Cooktop burners: orifice spuds replace orifice pud with Pull range out from countertop front about • Complete installation sectionsA-C 4 inches. There are two clips, one on each side, (Pages 3-4) before converting cooktop to natural located underneath the gas.
  • Page 9 If rangedoes not operate: Moving the range: Check that the circuit breaker is not tripped When moving range, slide range onto cardboard or the house fuse blown. or hardboard to prevent damaging the floor Check that the power supply cord is plugged covering.