Medium (15,000-18,500btu)+ heavy duty (22,000-28,500btu) air conditioner
Hide thumbs Also See for LRA257ST216:

Advertisement

FIG.7
FIG.8
!ii!iiii!iill
port b racket
ill L-:/ _'Sillangle bracket
_ Wooden strip
6. Install air conditioner into cabinet by following all steps in Step 9 of Window Mounting.
OPTIONAL: Caulking and installation of trim on interior wall may be done. You can buy wood from your local lumber or
hardware supply. On the outside, caulk opendings around top and sides of cabinet, and all sides of wood sleeve to the
opening.
• See Step 5, Item 4 of Window Mounting Instructions for bottom rail seal location.
Masonry Construction
1. Cut or build a wall opening in the masonry wall similar to the frame construction (refer to Step 2 of Thru-the-Wall
Installation for a wall thickness greater than 8-1/2").
2. Secure cabinet in place using masonry nails, or the right masonry anchor screws. (Another way to secure cabinet is
to build a frame in the masonry wall such as the one shown in Fig. 3 of Step 2 Prepare Wall. Securely anchor frame to
masonry wall. This way gives very good louver clearance on either side of cabinet.)
3. Install a lintel to support masonry wall above cabinet. Existing holes in cabinet can be used and/or additions holes
can be drilled to fasten cabinet at various positions. Be sure that side louver clearance is in accordance with Step 1
Select Wall Location.
4. Install exterior cabinet support brackets as shown in Step 3 of Thru-the-Wall
Installation. Caulk or flash if needed, to
provide a weather-tight seal around top and sides of cabinet.
5. To complete installation, apply wood trim molding around room side projection of cabinet.