Important Notes to the Installer
1. Read a llinstructions contained i nthese installation
instructions before installing t hecooktop.
2. Remove a llpacking material before connecting the
electrical supply t othecooktop.
3. Observe allgoverning c odes a ndordinances.
4. Besure to leave t hese instructions withtheconsumer.
5. Only certain cooktop models m ay beinstalled o ver
certain built-in electric o ven models. Approved
cooktops a ndbuilt-inovens a relisted bytheMFG ID
number andproduct code. ( Refer to theInformation
Sheet forthemodel n umbers).
Important Note to the Consumer
Keep these instructions withyourUse and
Care Guide for
future reference.
IMPORTANT
SAFETY
INSTRUCTIONS
• Be sure your cooktop is installed and grounded
properly
by a qualified
installer
or service
technician.
• This cooktop
must be electrically
grounded
in
accordance
with
local codes or, in their absence,
with the National
Electrical Code ANSI/NFPA No.
70--latest
edition
in the United States.
f!,,,vl,__=t_ll_t_The electrical
power
to the cooktop
must be shut off while
line connections
are being
made. Failure to do so could result in serious injury
or death.
Provide
Electrical
Connection
Install the junction box under the cabinet and run 120/
240 or 120/208 Volt, AC wire from the main circuit
panel. NOTE: DO NOT connect the wire to the circuit
panel at this time.
Electrical
Requirements
Observe all governing
codes and local ordinances.
1.
A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO
NOT fuse neutral. The fuse size must not exceed the
circuit rating of the appliance specified on the
nameplate.
2.
A circuit breaker or fused rated at 40 Amp is
required for this appliance.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70-
latest edition and local codes and ordinances.
An extension
cord must not be used
with this appliance.
Such use may result in a fire,
electrical
shock, or other personal
injury.
3.
The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from this appliance should
be connected directly to the grounded junction box.
The junction box should be located as shown in
Figure 2 with as much slack as possible remaining in
the cable between the box and the appliance, so it
can be moved if servicing is ever necessary.
4.
A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Unpacking
Instructions
1.
Unpack and visually inspect the cooktop.
2.
Be sure the bottle of cleaner conditioner packed in the
literature bag is left where the user can find it easily. It
is important that the ceramic-glass cooktop be
pretreated before use. See Cooktop Cleaning and
Maintenance
section in the Use and Care Guide.
Electrical
Connection
Connect the flexible armored cable that extends from
the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
junction box. Then make the electrical connection as
follows.
Electrical
ground
is required on this appliance.
This appliance
is equipped
with a
copper conductor
flexible
cable. If connection
is
made to aluminum
house wiring,
use only special
connectors
which are approved
for joining
copper
and aluminum
wires in accordance
with the
National
Electrical
Code and local codes and
ordinances.
Improper
connection
of aluminum
house wiring
to copper leads can result in a short
circuit or fire. Follow the connector
manufacturer
recommended
procedure
closely.
This appliance is manufactured with a supply wire and a
frame connected green or bare copper grounding wire.

Advertisement

loading

This manual is also suitable for:

E30ic75fss3E30ic75fss1E30ic75fss4