This appliance i smanufactured with a frameconnected
green (orbarecopper) g roundwire.
DONOTgroundto a gassupply pipe.
DONOTconnectto electricalpower supplyuntil
applianceis permanentlygrounded.Connect t he
groundwire beforeturning on the power.
If__your
appliance
is not equipped
with a white
neutral conductor:
Connect only to a 3-wire, 120/240V power supply; the
neutral conductor is not required for the operation of the
appliance. The potential at the power supply electrical
connections shall be 150V to ground or less.
NOTE TO ELECTRICIAN: The armored cable leads
supplied with the appliance are UL-recognized for
connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring. The
current carrying capacity of the conductor is governed by
the temperature
rating of the insulation around the wire,
rather than the wire gauge alone.
RISK OF ELECTRIC SHOCK: Grounding through the
neutral conductor is prohibited for new branch-circuit
installations (1996 NEC); mobile homes; recreational
vehicules; or in Canada, or in an area where local codes
prohibit grounding through the neutral connector.
Where
local
codes permit
connecting
the
appliance-grounding
conductor
to the
neutral
(white)
wire
(USA only):
Your appliance
has a 3-wire cable to be connected
to a 3-wire grounded
junction
box (see figure
4):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
Connect appliance and power supply cable wires as
shown in figure 4.
Cable from PowerSupply
Ground Wire
Red
Wires
Black
Wires
Ground Wire
(Bareor
Green Wire)
Box
U.L.-ListedConduit
Connector (or CSA
listed)
Cablefrom appliance
Figure 4 - U.S.A. Only
3-WIRE GROUNDED JUNCTION BOX
(If your appliance
is equipped
with
a
white
neutral
conductor,)
This appliance
is manufactured
with
a white
neutral
power
supply and a frame connected
copper
wire, The frame is grounded
by connection
of
grounding
lead to neutral
lead at the termination
of the conduit,
if used in USA, in a new branch
circuit installation
(1996 NEC), mobile home,
recreational
vehicles, where
local code do not
permit
grounding
trough
the neutral
(white)
wire
or in Canada, disconnect
the white
and green lead
from each other and use ground
lead to ground
unit in accordance with
local codes, connect
neutral
lead to branch circuit-neutral
conductor
in usual
manner
see Figure 6 or 7. If your appliance
is to
be connected
to a 3 wire grounded
junction
box
(US only), where
local code permit connecting
the appliance-grounding
conductor
to the neutral
(white)
see Figure 4 or 5.
Your appliance
has a 4-wire
cable to be connected
to a 3-wire grounded
junction
box (see figure
5):
1. Disconnect the power supply.
2. In the junction box:
Connect appliance and power supply cable wires as
shown in Figure 5.
Cable from PowerSupply
Ground Wire ,r _
Red Wires<
_
/-_
Black
_ires
1
, I_----
Junction
",_
Box
,--'J _Vhite Wire
""lJ.L.-ListedConduit
Connector ( or CSAlisted)
Cablefrom appliance
Figure 5 - U.S.A. Only
3-WIRE GROUNDED JUNCTION BOX