Power Supply Cord Kit (U.s.a.) - Frigidaire FES367AQC Installation Instructions Manual

30" electric slide-in range
Hide thumbs Also See for FES367AQC:
Table of Contents

Advertisement

Available languages

Available languages

1. Power Supply Cord Kit (U.S.A.)
The user is responsible for connecting the power supply
cord to the connection
block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic shielded copper cable), or by means of a
power supply cord kit. Only a power supply cord kit rated
at 125/250 volts minimum, 40 amperes and marked for
use with ranges shall be used. See chart for cord kit
connection opening size information.
Cord must have
either 3 or 4 conductors.
For mobile home, new installations, recreational
vehicles, or areas where local codes do not permit
grounding through neutral, a 4 conductor power supply
cord kit rated at 125/250 volts minimum, 40 amperes
and marked for use with ranges should be used (see
Figure 5).
Terminals on end of wires must be either closed loop or
open-end spade lugs with upturned ends. Cord must
have strain-relief clamp.
See below for 3 or 4 conductor wire connection.
!i!ili iii!il
¸ii!ii,!i!ilililsi
Refer to chart below
for proper
range connection
opening
size and power
supply cord kit ampere rating
information.
See serial plate on appliance
for
kilowatt
rating data.
See serial Plate on the
Appliance
for KW Rating
120/240
Volts
0 - 8.7 kw
8.8 - 16.5 kw
16.6 - 22.5 kw
120/208
Volts
Cord Kit
Ampere
Rating
0 - 7.8 kw
30 Amp
7.9-
12.5kw
40 Amp
12.6 - 18.5 kw
50 Amp
Diameter (inches (cm)) of
Appliance
Connection
Opening
Direct
Cord Kit
Connection
1 1/8 (2.9)
7/8 (2.2)
1 3/8 (3.5)
1 1/8 (2.9)
1 3/8 (3.5)
1 3/8 (3.5)
NOTE: Electric Slide-in Range is shipped from factory
with 1 1/8" (2.9 cm) dia. hole as shown on figure 4. If a
larger hole is required, punch out the knockout.
Risk of fire or electrical
shock exists if
an incorrect
size range cord kit is used, the
Installation
Instructions
are not followed,
or the
strain
relief
bracket
is discarded.
U.S.A. Style
Figure 1
Do not loosen the nuts which secure
the factory-installed
range wiring to terminal
block
while connecting range. Electrical failure or loss of
electrical connection may occur.
2. Factory
Connected
Power
Supply
Cord (Canada
only)
This range is equipped with a factory-connected
power
cord (see Figure 2). Cord must be connected to a
grounded 120/240 volt or 120/208 volt range outlet. If
not outlet is available, have one installed by a qualified
electrician.
Canada Style
Figure 2
Electrical
Shock
Hazard
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently
grounded.
• Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
• This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding
connector should be connected
to the grounding
terminal or wire lead on the
appliance.
Failure to do any of the above could result in a
fire, personal injury
or electrical shock.