Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and ! in. rear. Consideration
must be given to provide adequate clearance for installation and service.
ITI PREPARING FOR INSTALLATION
OF NEW DRYER
TIP:Install gour drger before installing gour washer.
This will allow better accesswhen installing dryer exhaust
REMOVING LINT FROM WALL
EXHAUST OPENING
• Removeand discardexisting plasticor metal foiltransition duct and
replacewith ULlistedtransitionduct.
WALL
INTERNALDUCT
CHECKTHAT EXHAUST
DAMPEROPENS
AND CLOSESFREELY.
Tiltthe dryer sideways
and removethe foam
shipping pads by
pulling atthe sides
and breakingthem
away from the dryer
legs. Besureto
remove all of the
foam piecesaround
the legs.
2
[]
ELECTRICAL CONNECTION
INFORMATION
A
WARNING-TO
REDUCE THE RISK OF
FIRE, ELECTRICAL
SHOCK AND PERSONAL
INJURY:
, DO NOT USE AN EXTENSION
CORD OR AN
ADAPTER
PLUG WITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local
codes, in accordance with the NATIONAL ELECTRICAL
CODE,ANSI/NFPA NO. 70.
ELECTRICAL REQUIREMENTS
This dryer must be connected to an individual branch circuit,
protected by the required time-delay fuses or circuit breakers. A
four or three-wire, single phase, !20/240V or !20/208V, 60Hz,
30 amp circuit is required.
GROUNDING
INSTRUCTIONS
This dryer must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding
conductor must be
run with the circuit conductors and connected to the equipment
grounding terminal on the appliance.
CONNECTING
DRYER USING 4-WIRE
CONNECTION
(MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTE: Since ganuarg
1, 1996, the National
Electric
Code
requires
that new constructions
utilize
a 4 wire connection
to an electric
drger.
REMOVEGROUND STRAP .
AND DISCARD.KEEPGREEN
GROUND SCREW
HOT
WIRE RELOCATE G REEN
GROUND SCREW
[RE
GREEN OR
YELLOW WIRE
COVER
/
S/4", UL
HOT
RECOGNIZED
WIRE
STRAINRELIEF
4 #i0 AWGMINIMUMCOPPER
CONDUCTORS O R120/240V 30A POWER
SUPPLY CORDKITMARKED FORUSE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP ORSPADE TERMINALS
WITH UPTURNED ENDS (NOTSUPPLIED1,