Download Print this page

Advertisement

Quick Links

Installation
Instructions
Gas Drger
10
If you hove any questions, coil 1-800-GECARES (US)or 1-800-561-3344 (Canada)
or Visit our Web site at: www.GEApplionces.com
(US)
PEDESTALS FOR DRYERS
(comes with individual installation instructions)
3 models available:
SBSD227F,SBSD137H
SBSDIO7H
BEFORE YOU BEGIN
Reed these instructions
completely end
carefully.
• IMPORTANT-
save t hese
instructions
forlocal inspector's
use.
• IMPORTANT-
Observe
all governing codesand ordinances.
• Note to Installer- Be sure to leave these
instructions with the customer.
• Note to Customer- Keep these
instructions with your Use and Care Book
for future reference.
• Before the old dryer is removed from
service or discarded, remove the dryer door.
• Inspect the dryer exhaust outlet and
straighten the outlet walls if they are bent.
• Service information and the wiring diagram
are located in the control console.
• Do not allow children on or in the appliance.
Close supervision of children is necessary
when the appliance is used near children.
• Install the dryer where the temperature is
above 50°F for satisfactory operation of
the dryer control system.
TOOLS YOU WILL NEED
(x2)
10" ADJUSTABLEWRENCHES
8" PIPEWRENCH
SLIPJOINT PLIERS
LEVEL
FLATBLADE SCREWDRIVER
, WAR
IN6- RISK OFFIRE
• To reduce the risk of severe injury or death, follow all installation instructions.
• Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance with local codes. In
the absence of local codes, installation must comply with National Fuel Gas Code,
ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSAB149.1.
• Ca/ifom/a Safe Drinking Water and Toxic Enforcement Act
This act requires the governor of California to publish a list of substances known to the state to
cause cancer, birth defects or other reproductive harm and requires businesses to warn
customers of potential exposure to such substances. Gas appliances can cause minor
exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and
soot, caused primarily by the incomplete combustion of natural gas or LPfuels. Properly
adjusted dryers will minimize incomplete combustion. Exposure to these substances can be
minimized further by properly venting the dryer to the outdoors.
This dryer must be exhausted to the outdoors.
Use only 4" rigid metal ducting for exhausting the clothes dryer to the outdoors.
DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal (semi-
rigid or foil-type) duct is installed, it must be UL-listed and installed in accordance with the
instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual. Flexible
ducting materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct dryer airflow and increase the risk of fire.
Do not install or store this appliance in any location where it could be exposed to water and or
weather.
Save these instructions. (Installers: Be sure to leave these instructions with the customer).
In the state of Massachusetts, installation
must be performed bg a qualified or
licensed contractor,
plumber, or gasfitter qualified or licensed by the state.
/4"DIA.METAL D UCT
(RECOMMENDED)
4" DIA.FLEXIBLE METAL ( SEMI-RIGID)
ULLISTED T RANSITION DUCT
(IFNEEDED)
KITWXO8X10077 (INCLUDES 2ELBOWS)
4" DIA,FLEXIBLE METAL ( FOIL TYPE)
ULLISTED T RANSITION DUCT
(IFNEEDED,)
MATERIALS YOU WILL NEED
PIPE
4" DIAM METALELBOW EXHAUST HOOD COMPOUND SOAPSOLUTION
FORLEAKDETECTION
(x2)
DUCT TAPE
4" DUCT CLAMPS
_"._J"
_
0 R
SA FETY GLASS ES
4" SPRING C LAMPS
FLEXIBLE GASLINE CONNECTORGLOVES
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Verify Your Gas Installation
(see section
2).
Prepare the Area and Exhaust
for Installation
of New
Dryer (see section
1).
Check and Insure the Existing
External
Exhaust is
Clean (see section
1) and Meets Attached
Installation
Specifications.
(see section
6).
Remove the Foam Shipping
Pads (see section
1).
Move the Dryer to the Desired Location.
Level Your Dryer (see section 8).
Connect
the Gas Supply (see section
3) and check for
leaks (see section
4).
Step 8
Connect the External Exhaust (see section 7).
Step 9
Connect the Power Supply (see section 5).
Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation
see section 9.
For Bathroom
or Bedroom
Installation
see section
10.
For Mobile or Manufactured
Home see section
11.
500A436P010
Pub# 31-16229

Advertisement

loading

Summary of Contents for GE DCVH680GJ2BB

  • Page 1 Installation Gas Drger Instructions If you hove any questions, coil 1-800-GECARES (US)or 1-800-561-3344 (Canada) or Visit our Web site at: www.GEApplionces.com (US) PEDESTALS FOR DRYERS , WAR IN6- RISK OFFIRE (comes with individual installation instructions) 3 models available: SBSD227F,SBSD137H • To reduce the risk of severe injury or death, follow all installation instructions. SBSDIO7H •...
  • Page 2 Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for proper operation and service. _] GAS REQUIREMENTS ITI PREPARING FOR INSTALLATION OF NEW DRYER...
  • Page 3 instructions Installation RECONNECTING GAS Listed connector ANSI Z21.24 / CSA 6.10 APPLY PIPECOMPOUND TO ALL MALE THREADS. 1/8" NPT PIPE PLUG FOR NEW METAL FLEXIBLE GAS INLETPRESSURE LINECONNECTOR SHUT-OFF ADAPTER 3/8" NPT ELBOW ITEMSNOT SUPPLIED PIPESIZE AT LEAST1/2" Note: The connector and fittings are designed for use only on the original installation and are notto be reused for another appliance or at another location.
  • Page 4 Installation Instructions rs-] ELECTRICAL CONNECTION [63 EXHAUST INFORMATION INFORMATION _I_WARNING - IN CANADA AND IN THE UNITED STATES, THE REQUIRED EXHAUST DUCT DIAMETER IS4 IN (102mm). DO NOT USE DUCT LONGER THAN SPECIFIED IN THE _l& WARNING-TO REDUCE THE RISK OF FIRE, EXHAUST LENGTH TABLE.
  • Page 5 instructions Installation EXHAUST CONNECTION STANDARD REAR EXHAUST (Vented above floor level} _1_ WARNING - TO REDUCE THE RISK ELBOW HIGHLY OF FIRE OR PERSONAL INJURY: * This clothes dryer must be exhausted to the outdoors. . Use only 4" rigid metal ducting for the home exhaust duct. Use only 4"...
  • Page 6 Installation Instructions, Exhausting CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT * For best drying performance, a rigid metal transition duct is recommended. * Rigid metal transitions ducts reduce the risk of crushing and kinking. UL-LISTED FLEXIBLEMETAL (SEMI-RIGID} TRANSITION DUCT EXCESSIVE * If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X!0077).
  • Page 7 Installation Instructions ADDING NEW DUCT DRYER EXHAUST TO LEFT OR BOTTOM OF CABINET FIXING HOLE _b, WARNING - PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE CABINET. LEFT SIDE REMOVE EXHAUST SCREW AND SAVE. Reconnect the cut portion (A)of the duct to the blower housing.
  • Page 8 Installation nstructions ADDING ELBOW FOR EXHAUST REVERSING THE DOOR SWING THROUGH BOTTOM OF CABINET IMPORTANT NOTES Insert the elbow through the rear opening and connect it to the drger internal duct Read the instructions all the wag through before starting. Applg duct tape on the joint between the drger internal duct Handle parts carefullg to avoid scratching paint and elbow, as shown on page 7.
  • Page 9: Before You Start

    Installation Instructions BEFORE YOU START Lag the door down on a soft protected flat surface so that the inner part faces upward (door resting on the handle side). 1. Unplug the drger from its electrical outlet. Remove the 6 large tapping screws (#10) located around the perimeter of the door outlining the gasket and the 2 machine screws (#8) on the hinge side.
  • Page 10 Installation Instructions REMOVE HINGE REINSTALL HINGE ASSEMBLY IMPORTANT: Note the location of the hinge (left or right) before 11. Place the hinge assemblg in the opposite side of the door. removing. Align the hinge holes with the door holes. With the door frame part of the door laid down on a protected soft surface, remove...
  • Page 11 Installation Instructions REINSTALL NUTS AND HINGE COVER REASSEMBLE DOOR ASSEMBLY IMPORTANT: Make sure there is no dirt or ang other foreign 14. Place the door on its edge. Assemble the 2 machine screws (#8),washers, and nuts. Tighten using a material in between the window panes.
  • Page 12 Installation Instructions REINSTALL DOOR ASSEMBLY 20. Turn the door over and fasten the outer door to the inner door using the 6 large tapping screws (#!0). 23. The door is now readg to be installed on the drger. To ease this step, the hinge has kegholes that allow a partiallg fastened screw to be used as a hook.
  • Page 13: Rough-In Dimensions

    ROUGH-IN DIMENSIONS 30 518" 40 114" 39 1/8" 53 518"...
  • Page 14 NOTES...