Download Print this page

GE JT3000SF1SS Installation Instructions Manual page 2

27" & 30" electric built-in wall ovens

Advertisement

Available languages

Available languages

r_==_
CUTOUT
FOR SINGLE OVENS IN WALL CABINET
NOTE: If the cabinet
does not have a front frame
and the sides are less than
sA" (1.9 cm) thick, shim
both sides equally
to establish
the cutout
width.
These ovens
are not
approved for
stackable
installations.
Opening
Between Inside
Wails Must be
at Least 28-1/2"
(724 cm) Wide
H
Sideby-Side Installations
Installtwo ovens in separate cutouts
Center Line
Center Line
]
so.s"177scrnl
]
I
30" models
I
]
2T' (68.58crn)
]
I
27" modes
!
I
!
--I
Cutout-
Cutout -
observeall
observe all
dimensionsand
dimensionsand
requirements
requirements
"---_1 I_== 2"Is1cm/r_in
Junction
Box
Location
(junction
box may
Jbe
located
in adjacent
cabinetl
: --T
22" (559
__-=_lm
cm}
Hin. to
_
Bottom of
J
Junction
J
BOX
J
..... ~%:;, ....
-" "
Cutou/Depth
(59.7cm} Nlin.
Note: Allow
1/4" (0.64 cm)
clearances
from side
edges of oven
door.
_____B___-_
t
F
G
...............................
L
......
t
C
m
4_
Recommended
Cutout Location
from Floor
32 1/2" (826 cm)
A ---d
Dimension
Dimension
Description
27" Single
Oven
30" Single
Oven
A
Cabinet
Width
27" (68.6 cm)
30" (76.2 cm)
B
Cutout
Width
25" (63.5 cm) min.
28½" (72.4 cm) min.
25½" (64.1 cm) max.
28sA " (72.7 cm) max.
C
Cutout
Height
27%" (70.2 cm) min.
27½" (69.2 cm) min.
28½" (71.4 cm) max.
27s4d ' (69.4 cm) max.
D
Overlap
of Oven Over
1" (2.5 cm)
_¼_d'(1.75 cm)
Side Edges of Cutout
E
Clearance
to
23" 150.8 cm) min.
23" 153.3 cm) min.
Adjacent
Corners,
Drawers,
Walls,
etc.,
When
Door Is Open
F
Overlap
of Oven
1" 12.5 cm) min.
1" 12.5 cm) min.
Top of Cutout
(11/4' ' 13.2 cm) for PT9050)
G
Overlap
of Oven
1" (2.5 cm) min.
1½" (3.2 cm)
Bottom
of Cutout
H
Junction
Box Location
8¾" (22.2 cm) max.
9½" (24.1 cm) max.
right side only
right side only
CUTOUT FOR SINGLE OVENS - UNDER COUNTER
NOTE: These
ovens are only approved
to be installed
under the specific
models
as labeled
on the unit.
Gas or Electric
Cooktops
May
Be Installed
Over
This Oven.
See Cooktop
Installation
instructions
for Cutout Size,
240V/208V
See Label
on Top of Oven for Approved
Models.
Junction
Box
Location
(junction
box
may be
in adjacent
cabinet)
25" (63.5 cm)
Gas and
Electrical
Connections
for Gas Cooktop
Must be Located
in an Adjacent
Accessible
Location
to the Right
MUST
SUPPORT
200 Ibs. (60 kg) FOR SINGLE
OVENS
MUST
SUPPORT
375 Ibs. (170 kg) FOR DOUBLE
OVENS
Side-by-Side
Installations
Install
two ovens in separate
cutouts.
center Line
CenterLine
I
30.5" (775 cm) 30" models
36" (91.4 cm)
Countertop
Height
Cutout - observe
all dimensions and
requirements.
__q
JL
Cutout
= observe
all dimensions
and
requirements.
_=2"
(5.l cm) Nlin.
NOTE:One cooktop may be centered over either oven in
the side-by-side installation.
Dimension
Dimension
Description
27" Single
Oven
30" Single
Oven
A
Cabinet
Width
25" (63.5 cm) min.
28½" (72.4 cm) min.
25¼" (64.1 cm) max.
28%" (72.7 cm) max.
B
Cutout
Height
27%" (70.2 cm) min.
27½" (69.2 cm) min.
28½" (71.4 cm) max.
27%d' (69.4 cm) max.
C
Unit Overlap
Top
1" (2.5 cm)
1" (2.5 cm)
(1VJ' (5.2 cm) for PT9050)
D
Unit
Overlap
Bottom
1" (2.5 cm)
l_/J ' (5.2 cm)
E
Unit
Overlap
Side Edges
1" (2.5 cm)
_¼_d'(1.75 cm)
F
Junction
Box Location
8sA" (22.2 cm) max.
9½" (24.1 cm) max.
right side only
right side only
Continue
to Section
4.

Advertisement

loading