Custom hood inserts
Table of Contents

Advertisement

Available languages

Available languages

Design Information
PRODUCT DIMENSIONS
ZVC36
The custom canopg must be sized to fit the insert
sleeve. Construct
the canopg with an opening
that is:
26'M/x
13-3/16"D
The opening must be constructed
of :3/4" thick
material to allow the sleeve locking clips to
engage.
The Supplied Liner
34-1/2"
21-1/4"
/'
I_
side
,,'
The stainless steel liner is shipped with each hood
insert. This non-combustible
liner protects the
underside of the canopy.
Custom Liner
If you are not using the supplied liner, you may
construct
a custom non-combustible
liner. Use the
supplied liner as a template.
The opening
must be
26"W x 13-3/16"D.
:3//4" thick material must
surround
the opening to allow the sleeve locking
clips to engage. The insert sleeve inside the cabinet
should be positioned
1/2" from the rear wall so
that the center of the 8" duct is 5-1/2" from the
rear wall.
Dimensions
and Specifications
(in inches)
Outside Dimensions
27-1/2"
"1
The Insert Sleeve
14"
112"
!2"
25 -3/4" -
112"
The bottom edge of the insert sleeve has a 7/8"
wide flange on the sides and a 1/2" wide flange
on the front and back.
Remote Location for the Control
The control may be removed from the hood
and installed into a wall or countertop.
A 30-ft.
length of wire is supplied to accommodate
most
installations.
A blanking plate covers the opening
when the controls are removed.
The overall size of the control
is 4-1/4" wide and
2-1/4" deep.
3-11116"
1-11/16"
Control cutout
We recommend
that the cutout in granite or other
hard surfaces be made before the countertop
is
installed.