Displayed Text
Event Log Text
TEMP FLT:PsU
Temp Fault: Power
supply Unit
TEMP FLT:VC
Temp Fault: speaker
Voice Coil
TEMP WARN:CH
Temp.warning; Channel
TEMP WARN:MAG
Temp.Warning; speaker
Magnet
TEMP WARN:VC
Temp.Warning; speaker
Voice-Coil
UNCERTAIN LOAD
Uncertain About Load
Type
UNDER sPkR CNT
Under speaker Count
VHF FAULT
Channel Fault: Very
High Frequency
VOLTAGE CLIP
n/a
WRONG LOAD
Load Type / Routing
Mismatch
Category
Type
Fault
Power supply
temperature
Fault
Speaker Voice Coil temperature
fault
Warning
Power output
temperature warning
Warning
Speaker magnet
temperature
Warning
Speaker voice coil
temperature
Warning
Load uncertainty
Warning
Fewer Speakers
Fault
VHF at output
Fault
Voltage limiter active
Fault
Load type mismatch
Table 11.1: Faults and warnings overview
APPENDIX 11
Description
The temperature of the PLM's PSU has exceeded
its safety limit
The temperature of the speaker voice coil
(estimated by SpeakerSafe) has exceeded the
manufacturers' recommended maximum
High temperature in the power output stage
The temperature of the speaker magnet is high
(estimated by SpeakerSafe)
The temperature of the speaker voice coil is high
(estimated by SpeakerSafe)
When speaker Fingerprints are taken a tolerance
band is also defined to take into account production
variations. If LoadSmart results lie in this band a
Load uncertainty warning results. The user should
re-check the load and if all appears to be correct it is
likely that normal operation will result.
A higher load impedance has been measured than
was predicted by the Load Library for the assigned
speaker type
An exceptionally high level of continuous HF has
been detected at the PLM's power output stage
The peak voltage at the output terminals has
exceeded the user-defined safe maximum.
LoadSmart is measuring load characteristics which
differ from those of the assigned speaker type