Lab.gruppen PLM Series PLM 10000Q Quick Start Manual
Lab.gruppen PLM Series PLM 10000Q Quick Start Manual

Lab.gruppen PLM Series PLM 10000Q Quick Start Manual

Plm series powered loudspeaker management™ systems
Hide thumbs Also See for PLM Series PLM 10000Q:

Advertisement

Quick Links

Quick Start and Field Reference Guide
PLM
Powered Loudspeaker Management
Rev. 1.0.3
Item no. QSG-PLM
Series
systems

Advertisement

Table of Contents
loading

Summary of Contents for Lab.gruppen PLM Series PLM 10000Q

  • Page 1 Quick Start and Field Reference Guide ™ Powered Loudspeaker Management Rev. 1.0.3 Item no. QSG-PLM Series systems ™...
  • Page 2: Table Of Contents

    3.3.2 Speaker output hazard ...4 3.3.3 Radio interference ...4 3.3.4 Speaker damage ...4 3.3.5 Maintenance ...4 4 WELCOME ...5 additional Documentation ...5 4.2.1 Lab.gruppen documents ...5 5 INSTALLATION ...6 unpacking ...6 5.2 Mounting ...6 5.3 Rear Mounting ...6 5.4 Cooling ...7 5.5 operating Voltage ...8...
  • Page 3: Approvals 2

    this equipment conforms to the requirements of the EMC Directive 2004/108/EC and the requirements of the Low Voltage Directive 2006/95/EC. Standards applied: EMC Emission En55103-1, E3 EMC immunity En55103-2, E3, with S/n below 1% at normal operation level. Electrical Safety En60065, Class i this equipment is tested and approved according to the u.S.
  • Page 4: User Responsibility

    3 WArNINGs 3.3 User Responsibility 3.3.1 Mains connection grounding Your PLM must be connected to a grounded socket outlet. 3.3.2 Speaker output hazard PLMs are capable of producing hazardous output voltages. to avoid electrical shock, do not touch any exposed speaker wiring while the PLM is operating.
  • Page 5: Welcome 4

    4.1 Introduction thank you for choosing the Lab.gruppen PLM Series of Powered Loudspeaker Management systems for your sound reinforcement needs. We are confident that you will be pleased with the performance, unique features, configuration flexibility, reliability, and long- term durability offered by PLM Series products.
  • Page 6: Installation

    Carefully open the shipping carton and check for any damage to the PLM or the supplied accessories. Every Lab.gruppen product is tested and inspected before leaving the factory and should arrive in per- fect condition. if any damage is discovered, please notify the shipping company immediately.
  • Page 7: Cooling

    Figure 5.3a : Use washer for fixed installation Figure 5.3b : Use tube for slide-on installation INsTAllATON 5 5.4 Cooling the PLM uses a forced-air cooling system with airflow from front to rear, allowing high continuous power levels without thermal problems. (Front-to-rear airflow is preferable as air at the front of a rack is cooler than that at the rear in nearly all situations.) never attempt to reverse the airflow.
  • Page 8: Operating Voltage

    5 INsTAllATON 5.5 Operating Voltage the label adjacent to the mains (aC) input con- nector indicates the aC mains voltage for which your PLM is wired and approved. the PLM Series is available in two versions: 115 V and 230 V. Connect the mains cable (aC cord) only to an aC source of the voltage shown on the label.
  • Page 9: Quick Start Tutorial 6

    6.1 Introduction this section covers installation of the Dolby Lake Controller (DLC) PLM Edition software, input and output connections, basic functionality, and setup instructions. the information will allow a user to achieve a basic level of understanding of the PLM Series system architecture while also setting up the unit for a basic system application.
  • Page 10 4.2 for download links. 6.3.2 Software and firmware Updates Both Lab.gruppen and Dolby Lake strive to improve and update the capabilities of PLM Series products. Many of these improvements are available to PLM Series users as free updates of the Dolby Lake Controller PLM Edition software application and PLM Series firmware.
  • Page 11: How To Configure The Plm

    6.4 how to Configure the pLM the following tutorial presents a “walk-through” of the steps involved in a typical loudspeaker system configuration. it will allow the user to become familiar with the basic structure and operation of the PLM Series implementation of Dolby Lake processing. this tutorial employs the Dolby Lake Controller (DLC) PLM Edition software, though some steps are accessible via the PLM’s front panel.
  • Page 12 Digital Clock: internal – 96 kHz • • input Configuration: auto: auto; type: ana- log; offset/Headroom: 26 dBu Dante Configuration: Dante Disabled • analog iso-Float & aES termination: inputs • 1-2: Floating; aES: terminated. Guide Figure 4: Output configuration page...
  • Page 13 LF, MF, HF and sub channels. alternatively, a Lab.gruppen LoadLibrary file would have been used that would already contain the necessary data to configure gain, crossover and limiter settings.
  • Page 14: Gain Settings

    6 QUICK sTArT TUTOrIAl 6.5 Gain Settings the architecture of the PLM Series provides gain adjustments at a number of points in the signal flow path. thus, there are many places in which one can adjust the levels in the PLM. Each point serves a different purpose.
  • Page 15: Gain / Level Optimization

    PLM. this control replaces the traditional knob found on conventional amplifiers. it should typically be left at 0 dB during use. (adjust in Lab.gruppen info, Status tab) Amp Gain Corresponds to the gain that you would have available in a conventional system if the amplifier section was outside the PLM.
  • Page 16: Controls And Connections

    7 CONTrOls AND CONNECTIONs 7.1 front panel the PLM’s front panel is based around a 2.5” daylight- readable backlit liquid crystal display (LCD), through which control and monitoring of most functions are performed via a simple menu system. Controls are grouped in two switch clusters alongside the display;...
  • Page 17 automatically cancel after two minutes if no further mute actions are taken. Meter the MEtER button scrolls through three alternative views: HoME, MoDuLE, and tEMPERatuRE. Pressing MEtER when in MEnu mode returns the screen to MEtER mode, and the HoME view is displayed.
  • Page 18: Rear Panel

    7 CONTrOls AND CONNECTIONs 7.2 Rear panel SPEAKER OUTPUTS CH 2 CLASS 2 WIRING Ser. N:o Removed! SPEAKER OUTPUTS 1+/- CH 1+/- 1+/- CH 1+/- 3+/- CH 3+/- 1+/- CH 3+/- CLASS 2 WIRING 2+/- CH 2+/- 2+/- CH 2+/- 4+/- CH 4+/- 2+/- CH 4+/- 7.2.1.
  • Page 19: Power Output Connectors

    8-pole neutrik Speakon connec- tor, and on two 4-pole neutrik Speakon connectors. the two 4-pole connectors carry the power outputs of channels 1 & 2 and 3 & 4 respectively. the figure below shows the proper wiring scheme for these Speakon outputs.
  • Page 20: Technical Specifications

    Intercooler and Class TD are national and/or international registered trademarks of Lab.gruppen AB. PLM, Powered Loudspeaker Management, R.SMPS, LoadLibrary, LoadSmart, SpeakerSafe and ISVPL are trademarks of Lab.gruppen AB. Dolby, Lake, and the double-D symbol are registered trademarks of Dolby Laboratories. Dolby Lake Processor, Lake Contour, Lake Mesa Quad EQ, LimiterMax and Iso-Float are trademarks of Dolby Laboratories.
  • Page 21: Warranty 9

    Technical assistance and service International if your Lab.gruppen product requires repair, contact your Lab.gruppen dealer or distributor, or contact Lab.gruppen by fax or email to obtain the location of the nearest authorized service centre. factory service in the event Lab.gruppen product requires factory service, you may contact Lab.gruppen’s service...
  • Page 22 L a b . g r u p p e n a b • S w e d e n i n t e r n a t i o n a L c o n t a c t • i n f o @ L a b g r u p p e n . c o m u S c o n t a c t •...

This manual is also suitable for:

Plm 10000q