Download Print this page
Kenmore 79090153409 Installation Instructions Manual
Kenmore 79090153409 Installation Instructions Manual

Kenmore 79090153409 Installation Instructions Manual

24" electric range

Advertisement

Available languages

Available languages

Quick Links

United States
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL
INSPECTOR'S
USE.
READ AND
SAVE THESE INSTRUCTIONS
FOR FUTURE
REFERENCE.
pr_
FOR YOUR SAFETY: Do not store or use gasoline
or other
flammable
vapors
and liquids
in the vicinity
of this or any other appliance.
le
Clearances
and Dimensions
a.
Provide adequate
clearances
between the range and adjacent
combustible surfaces.
b.
Location--Check
location where the range will be installed.
Check for proper electrical
supply and the
stability
of floor.
c.
Dimensions
that are shown must be used. Given
dimensions
provide
minimum
clearance.
Contact
surface
must be solid and level.
FRONT
.................
......
........
Minimum
T
Minimum
to
Minimum
to
cabinets
wall
on either
1/16"_
18"
on
either
side
side of
range.
_ _r
of range.
SIDE
VIEW
J_- 13"-_J
Maximum
depth
_
for cabinets
above
range
top.
36"
_
I1!
B m._
BACK
VIEW
Terminal
Block
FRONT
VIEW
RANGE
C
24"
24"
DIMENSIONS
A
B
24"
25"
48"
Maximum
45"
Door
Open
\
36" _+ 1/8")
\
30" MINIMUM
CLEARANCE BETWEEN THE TOP OF THE COOKING
SURFACE AND THE BOTTOM OF AN
UNPROTECTED WOOD
OR METAL CABINET; OR 24" MINIMUM
WHEN
BOTTOM
OF WOOD
OR METAL
CABINET iS PROTECTED BY NOT LESS THAN I/4"
FLAME RETARDANT MiLLBOARD
COVERED WiTH NOT
LESS THAN NO. 28 MSG SHEET STEEL, 0.015" STAINLESS STEEL, 0.024" ALUMINUM
OR 0.020" COPPER. 0"
CLEARANCE iS THE MiNiMUM
FOR THE REAR OF THE RANGE. FOLLOW ALL DiMENSiON
REQUIREMENTS
PROVIDED
ABOVE
TO PREVENT PROPERTY DAMAGE,
POTENTIAL
FiRE HAZARD,
AND
iNCORRECT
COUNTERTOP AND CABINET CUTS.
TO ELIMINATE
THE RISK OF BURNS OR FIRE BY REACHING
OVER HEATED SURFACE UNITS, CABINET
STORAGE SPACE LOCATED ABOVE
THE SURFACE UNITS SHOULD
BE AVOIDED.
IF CABINET
STORAGE
IS TO BE PROVIDED,
THE RISK CAN
BE REDUCED
BY INSTALLING
A RANGE
HOOD
THAT PROJECTS
HORIZONTALLY
A MINIMUM
OF 5" BEYOND THE BOTTOM OF THE CABINETS.
Printed in Canada
P/N 318201715 (1201) Rev. A

Advertisement

loading

Summary of Contents for Kenmore 79090153409

  • Page 1 United States INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 4B. Models Requiring Power Supply Cord Kit 2. Install Anti-Tip Bracket(s). (See instructions RiSK OF FiRE OR ELECTRICAL an page 4.) SHOCK MAY OCCUR iF AN iNCORRECT SiZE RANGE CORD KiT IS USED, THE INSTALLATION 3. Serial Plate Information iNSTRUCTiONS ARE NOT FOLLOWED OR STRAIN The serial plate...
  • Page 3 To Remove Ground 8x32 Link: From ... Range range Remove ground link ..A,, Terrain a Some _rl _] screw using a Phillips screwdriver. Save L_ne 2 ..Models Ground screw for future use. link silver !/\\ Neutral ..colored.__ _\ ..<_| (whi=e or Bend up ground link...
  • Page 4 8. Anti-tip Bracket Installation Instructions A. Lacate the Bracket Using the Template - Locate the bracket position by placing the template on the important Safety Warning floor, against the back wall and on the right edge of To reduce the risk of tipping of the range, the range cabinet.
  • Page 5 C. Level and position the rang_e_ = Slide range to its Range flnat position, Insert the range leveling teg in the anti- Leveling. A/_! i_/ tip bracket. Visually verify if the anti-tip bracket x_:_"_L_ Anti= Ti P engaged. Lower the range by adjusting the 4 leveling Bracket...
  • Page 7 LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR Estados Unidos CALIFICADO. IMPORTANTE" GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA. PARA SU SEGURIDAD: No almacene ni utilice gasolina u otros vapores y liquidos inflamables...
  • Page 8 4B. Modelos clue requieren Juego de Cord6n Jnstale soportes antivuelCOo (Ver instrucciones en la p6gina 4.) ministro de Energ_a PUEDE OCURRIR RIESGO Placa de Jdenfificaci6n INCENDIO O DESCARGA ELE_CTRICA SI SE USA UN Esta ptaca de identificaci6n est6 localizada sabre CORDON DE ESTUFA DE CALIBRE INCORRECTO;...
  • Page 9 Para qultar la uni6n a tierra: Tuerca Quite et tornitto de la hexagonal _CaJade laTerminalestufa uni6n a tierra usando de 8 x 32 destornittador Phillips. L/nea2 Guarde el tornilto para usa futuro. Doble la uni6n a tierra hacia arriba para que no Tornilla de entre en contacto con la...
  • Page 10 8. instrucci6n para la instalaci6n A. Localice la Njaci6n usando el papeJ modelo- LocaNce la posici6n de la fijaci6n colocando braquete anti-basculante plantiNa en et piso pegada a la pared y la oritla Nora importante de seguridad derecha del gabinete. Marque la ubicaci6n de los...
  • Page 11 C. Nivele la cocina V co]oque la cocina en su lujgar. = Deslice ta estufa a su lugar. Cotocar la pata nlvelador J_/o_b! I_1 niveladora dentro del braquete anti-bascutante. Veriflque visuaimente que tos soportes antivuelco de anti- es|u_a est6n correctamente engonchados (andados).