United States
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL
INSPECTOR'S
USE.
READ AND
SAVE THESE INSTRUCTIONS
FOR FUTURE
REFERENCE.
pr_
FOR YOUR SAFETY: Do not store or use gasoline
or other
flammable
vapors
and liquids
in the vicinity
of this or any other appliance.
le
Clearances
and Dimensions
a.
Provide adequate
clearances
between the range and adjacent
combustible surfaces.
b.
Location--Check
location where the range will be installed.
Check for proper electrical
supply and the
stability
of floor.
c.
Dimensions
that are shown must be used. Given
dimensions
provide
minimum
clearance.
Contact
surface
must be solid and level.
FRONT
.................
......
........
Minimum
T
Minimum
to
Minimum
to
cabinets
wall
on either
1/16"_
18"
on
either
side
side of
range.
_ _r
of range.
SIDE
VIEW
J_- 13"-_J
Maximum
depth
_
for cabinets
above
range
top.
36"
_
I1!
B m._
BACK
VIEW
Terminal
Block
FRONT
VIEW
RANGE
C
24"
24"
DIMENSIONS
A
B
24"
25"
48"
Maximum
45"
Door
Open
\
36" _+ 1/8")
\
30" MINIMUM
CLEARANCE BETWEEN THE TOP OF THE COOKING
SURFACE AND THE BOTTOM OF AN
UNPROTECTED WOOD
OR METAL CABINET; OR 24" MINIMUM
WHEN
BOTTOM
OF WOOD
OR METAL
CABINET iS PROTECTED BY NOT LESS THAN I/4"
FLAME RETARDANT MiLLBOARD
COVERED WiTH NOT
LESS THAN NO. 28 MSG SHEET STEEL, 0.015" STAINLESS STEEL, 0.024" ALUMINUM
OR 0.020" COPPER. 0"
CLEARANCE iS THE MiNiMUM
FOR THE REAR OF THE RANGE. FOLLOW ALL DiMENSiON
REQUIREMENTS
PROVIDED
ABOVE
TO PREVENT PROPERTY DAMAGE,
POTENTIAL
FiRE HAZARD,
AND
iNCORRECT
COUNTERTOP AND CABINET CUTS.
TO ELIMINATE
THE RISK OF BURNS OR FIRE BY REACHING
OVER HEATED SURFACE UNITS, CABINET
STORAGE SPACE LOCATED ABOVE
THE SURFACE UNITS SHOULD
BE AVOIDED.
IF CABINET
STORAGE
IS TO BE PROVIDED,
THE RISK CAN
BE REDUCED
BY INSTALLING
A RANGE
HOOD
THAT PROJECTS
HORIZONTALLY
A MINIMUM
OF 5" BEYOND THE BOTTOM OF THE CABINETS.
Printed in Canada
P/N 318201715 (1201) Rev. A