example 2. Reset a RAID5 system
1. A TryRAID5 volume was built with three hard disks, we want to reset one of them.
Select "3. Reset Disks to Non-RAID" in main menu and press <Enter>.
Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5
Copyright(C) 2003-04 Intel Corporation All Rights Reserved.
1 . Create RAID Volume
2. Delete RAID Volume
RAID Volume :
ID
Name
0
0
TryRAID5
TryRAID5
Physical Disks:
Port Drive Model
0
Hitachi HDS72161
Hitachi HDS72161
1
ST380811AS
2
SAMSUNG HD161HJ S0V3J9APA30524
3
ST380815AS
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu
2. A warning message is displayed.
3. Select "Port 2 - SAMSUNG HD161HJ" hard disk as the one to be reset. Press
<Enter>. A double confirmation message pops out, press <Y> to confirm.
Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5
Copyright(C) 2003-04 Intel Corporation All Rights Reserved.
1. Create RAID Volume
1 . Create RAID Volume
2. Delete RAID Volume
3. Reset Disks to Non-RAID
RAID Volume :
ID
Name
Port Drive Model
0
0
TryRAID5
TryRAID5
0
1
Physical Disks:
► 2 2
Port Drive Model
2
0
Hitachi HDS72161
Hitachi HDS72161
1
ST380811AS
2
SAMSUNG HD161HJ S0V3J9APA30524
3
ST380815AS
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu
Intel(R) Rapid Storage Technology - Option ROM - 10.0.0.1032
Copyright(C) 2003-10 Intel Corporation. All Rights Reserved.
[ DISK/VOLUME INFORMATION ]
Level Stripe
RAID5(Parity) 64KB 149.1GB Normal Yes
RAID5(Parity)
Serial #
PVF904�21G2J�M
PVF904�21G2J�M
PVF904�21G2J�M
5PS1TAGW
S0V3J9APA30524
5RW1CA37
Intel(R) Rapid Storage Technology - Option ROM - 10.0.0.1032
Copyright(C) 2003-10 Intel Corporation. All Rights Reserved.
[ RESET RAID DATA ]
Resetting RAID disk will remove its RAID structures
and revert it to a non-RAID disk.
[ DISK/VOLUME INFORMATION ]
WARNING: Resetting a disk causes all data on the disk to be lost.
( This does not apply to Recovery volumes)
Level Stripe
Serial #
RAID5(Parity)
RAID5(Parity) 64KB 149.1GB Normal Yes
Hitachi HDS721616PLA PVF904�21G2J�M
Hitachi HDS721616PLA
ST380811AS
SAMSUNG
SAMSUNG HD161HJ
SAMSUNG HD161HJ
Serial #
PVF904�21G2J�M
PVF904�21G2J�M
PVF904�21G2J�M
5PS1TAGW
S0V3J9APA30524
5RW1CA37
Select the disks that should be reset.
[↑↓]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
[↑↓]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
[ MAIN MENU ]
3. Reset Disks to Non-RAID
4. Recover Volume Options
5. Exit
Size Status Bootable
64KB 149.1GB
Size Type/Status(Vol ID)
149.0GB
149.0GB
149.0GB
74.5GB
149.0GB
149.0GB
149.0GB
74.5GB
[ MAIN MENU ]
3. Reset Disks to Non-RAID
5. Acceleration Options
6. Exit
Size Status Bootable
Size Status
64KB 149.1GB
149.0GB Member Disk
5PS1TAGW
5PS1TAGW
74.5GB
74.5GB
74.5GB
S0V3J9APA30524
S0V3J9APA30524
149.0GB Member Disk
149.0GB Member Disk
149.0GB Member Disk
S0V3J9APA30524
S0V3J9APA30524
S0V3J9APA30524
Size Type/Status(Vol ID)
149.0GB Member Disk
149.0GB Member Disk
149.0GB Member Disk
149.0GB
149.0GB
149.0GB
74.5GB
149.0GB
149.0GB
149.0GB
74.5GB
94
Member Disk(0)
Member Disk(0)
Member Disk(0)
Non-RAID Disk
Member Disk
Member Disk
Member Disk
Member Disk
Member Disk
Member Disk
Member Disk
Member Disk(0)
Member Disk(0)
Member Disk(0)
Non-RAID Disk

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents