Haier AS102ALARA Operation Manual

Digital dc variable frequency healthy split air conditioner
Hide thumbs Also See for AS102ALARA:

Advertisement

SPLIT AIR CONDITIONER
OPERATION
MANUAL
AS102AMARA
AU102ACARA
(HSU-10HA03(DB))
AS102ALARA
AU102ACARA
(HSU-10H03(DB))
AS122AYARA
AU122ACARA
(HSU-12HA03(DB))
AS122AVARA
AU122ACARA
(HSU-12H03(DB))
Digital DC Variable Frequency
Healthy Split Air Conditioner
Please read this manual carefully before use.
Please keep this manual carefully and safely.
No.0010540438
I

Advertisement

Table of Contents
loading

Summary of Contents for Haier AS102ALARA

  • Page 1: Operation Manual

    SPLIT AIR CONDITIONER OPERATION MANUAL AS102AMARA AU102ACARA (HSU-10HA03(DB)) AS102ALARA AU102ACARA (HSU-10H03(DB)) AS122AYARA AU122ACARA (HSU-12HA03(DB)) AS122AVARA AU122ACARA (HSU-12H03(DB)) Digital DC Variable Frequency Healthy Split Air Conditioner Please read this manual carefully before use. Please keep this manual carefully and safely. No.0010540438...
  • Page 2: Table Of Contents

    Contents Cautions...1-2 Name of Parts...3-4 Operation Hints...5-6 Operation...7-13 Notes for Safety...14-15 Maintenance... 16-18 Trouble Shooting...19-21 Installation...22-30 Installation Check and Trial Operation...31...
  • Page 3: Cautions

    Disposal of the packaging of your new air conditioner Use of the air conditioner is to be carried out in strict compliance with the relavtive All the packaging materials employed in the instructions set forth in the User's Guide.
  • Page 4 European region allowed to sit on the outdoor unit. Installation Check and Trial Operation Please operate the air conditioner in accordance with this Operation Manual Check items for the Trial Operation(Tick Is the connector leaked? How is the connector insulated?
  • Page 5: Name Of Parts

    8. Emergency Manual Button When the remote controller is lost or cannot be used, this button can make the air conditioner continue to operate for the time being. 9. Remote Signal Receiving Window Wrong Pressing It receives the remote signal from the remote controller.
  • Page 6 To display the temperature set 12. Temperature Set To set the desired room temperature 13. On/Off Button To turn on and turn off the air conditioner 14. Air Volume To select the desired air speed 15. Air flow Direction To adjust the air flow direction 16.
  • Page 7: Operation Hints

    2.Install the Drain Elbow The elbow is only used for the thermal pump type air conditioner.And the cold air type air conditioner does not need it.The elbow shall be installed as per the drawing.The drain elbow is not used in a very cold weather(the air temperature is below 0 for long).
  • Page 8: Operation Hints

    Notes When heating, the air conditioner takes a lot of heat from outdoor and release the heat into the room , therefore the outdoor temperature will affect the heating effect.
  • Page 9: Operation

    Installation Localize the Installation: Indoor Unit Install the indoor unit where the weight of the unit can be supported. Install the indoor unit where the head source and steam source are not close and the unit inlet and outlet are not blocked. Install the indoor unit where the drainage is easy and the outdoor unit can easily connected.
  • Page 10 The remote controller will be self-checked after loading the new batteries by displaying all the symbols and resume working very soon. Health Operation 1. After turning on the air conditioner, set to the desired mode: The remote controller displays the mode selected, the power light on the indoor unit lights up.
  • Page 11 A specialized power supply wire, which shall be installed by a competent person as per the rules of the national standard. Power supply socket must be close to the air conditioner. And the socket must have an earth to make the air conditioner be grounded through the power supply socket.
  • Page 12 The remote controller will remember the current swing position, and each time when you turn on the air conditioner, the swing louver will automatically stop at the position set previously. Approx.
  • Page 13 With the time set function, the air conditioner can be turned on and off automatically at your set time. You can let your air conditioner be turned on or off automatically after you wake up in the morning, Mounting Plate before you come back from work in the evening, or after you fall asleep at night.
  • Page 14 When a power failure suddenly occurs during the air conditioner is working after the power failure resume is set, if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being resumed after the power is supplied again, or press the button after the power comes again.
  • Page 15 Si Si would be heard. sound "Si Si" is due to generation of anion. Please check your air conditioner as the procedure below before contacting the local maintenance center for after sales service: The air conditioner cannot be started...
  • Page 16: Notes For Safety

    Notes for Safety The power supply plug must have the earth line After electric wiring , the air conditioner shall be electrified to check for electric leakage. to ensure that the air conditioner may be grounded effectively through the power supply socket.
  • Page 17 Turn on the machine and let it operate for half a day under the status of sending air in a sunny day so as to make the inside of the air conditioner fully dry. Clean the dust filter, the indoor unit, and outdoor unit, then cover it.
  • Page 18: Installation

    Air Filter Instructions. Hints: This model of air conditioner falls into two types: one is with a multiple light catalysis air filter, the other with an air filter without multiple light catalysis. So the maintenance should be done...

Table of Contents