Alert Settings - Dukane 8970 User Manual

Network guide
Hide thumbs Also See for 8970:
Table of Contents

Advertisement

3.1 Projector Web Control (continued)

3.1.6 Alert Settings

Item
Cover Error
Fan Error
Lamp Error
Temp Error
Air Flow Error
Cold Error
Filter Error
Other Error
Schedule Execution
Error
Lamp Time Alarm
Filter Time Alarm
Filter Status Notification The status to clean the air filter is changed.
Transition Detector
Alarm
Cold Start
Authentication Failure
Refer to
Troubleshooting in the Operating Guide for further detailed
&
explanation of Error except Other Error and Schedule Execution Error.
Displays and configures failure & alert settings.
The lamp cover has not been properly fixed.
The cooling fan is not operating.
The lamp does not light, and there is a possibility that interior
portion has become heated.
There is a possibility that the interior portion has become heated.
The internal temperature is rising.
There is a possibility that the interior portion has become
overcooled.
Filter time over.
Other error.
If displaying this error, please contact your dealer.
Schedule Execution error. (
Lamp time over Alarm Time setting.
Filter time over Alarm Time setting.
Transition Detector Alarm. (&SECURITY menu in the
Operating Guide)
When the projector is supplied with the power, it works as
below.
• If the STANDBY MODE is set to the NORMAL:the projector's
power status changes from "OFF" to "Standby state".
• If the STANDBY MODE is set to the SAVING:the projector's power
status changes from "Standby state" to "ON (lamp is turned on)".
(&SETUP menu in the Operating Guide)
The SNMP access is detected from the invalid SNMP community.
Description
)