Power Control Panel; Master Curcuit -Breaker; Ac Power Input - Bryston 9BSST-THX Owner's Manual

Sst series amplifiers
Table of Contents

Advertisement

. Master circuit - breaker.
The 9BSST uses a magnetic-trip circuit breaker (1) to protect the amplifier.
This switch should be 'OFF' when installing the 9BSST. When switched 'OFF'
all A/C power is removed from the amplifier, including standby power.
The circuit breaker is not the day to day power switch and should be switched
and left 'ON' after the installation is complete.Use the 'ST POWER" switch or
an external control voltage to Power-up or Power-down the amplifier.
Should the breaker trip, lower or remove the amplifier input signals. Switch
the breaker to the 'ON' position. Then power the unit up normally. The circuit
breaker must be 'ON' at all times for the 9BSST to operate.

2. AC power input.

This is a high current plug for the power cord receptacle. Check that the volt-
age rating at the right of the connector conforms with your locality. With the
circuit breaker 'OFF' insert the power cord into the 9BSST, then plug the other
end to an approprate A/C power outlet.
3. Power-Up ( Local / Auto switch. )
A. In "Local" position either the front panel 'ST POWER" switch or an
external voltage controls the power-up of the 9BSST.
B. "Auto" is used when the 9BSST is powered from a switched power outlet.
The 'ST POWER' switch and / or control voltage will function normally
after the initial power up.
4. External control voltage power up ( Local / external switch.)
A. To power-up the 9BSST using an external control voltage,
Supply a 4v to 12v A/C or DC control voltage to the 'IN' terminals of connector ( 5 ).
Use paired wire of 22 gauge to 18 gauge sufficient in length between the source device and the 9BSST. (see 'W' )
Select switch (4) to "External". The amplifier will now power-up only when the control voltage is present (on).
Immediately following power up, the control voltage will appear at the 'OUT' terminals of connector (5) for the control
of other equipment.The Removal of the control voltage ( 0v) causes the 9BSST to turn 'off' and the control voltage at
the 'OUT' terminals is interrupted.
B
. In the"Local" setting of switch (4) the 9BSST will ignore the control voltage, and power up only by using the
front panel 'ST POWER' switch, or as in section 3 above. If a control voltage is present at the 'IN' terminals it
will still be available at the 'OUT' terminals after the power-up sequence.
Note:
The 'OUT' terminals are connected to the 'IN' terminals once the 9BSST has powered-up.
The control current is determined by the source equipment. The carrying current of the 'OUT' relay is 2 amps.
The 9BSST itself draws less than 2 mA from the control current when operating.

Power Control Panel

to other voltage controlled devices
RS-232
EXP.
RISK OF ELECTRIC SHOCK - DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
SERIAL NUMBER
SP1-
12V TRIG. OUT
AUX. IR
OPT1
OPT2
F2A 250V
MUTE
C
ON/OFF
CONTROL VOLTAGE SOURCE
9BSST THX
FIVE CHANNEL POWER AMPLIFIER
1
2
3
5
4
Control voltage wire preparation
for screw terminal connector
120V
60Hz
20W
separate 1"
fig W
18 to 22
1/4"
strip
gauge
wire
5

Advertisement

Table of Contents
loading

Table of Contents