be a 5 volt logic level, should be ≥2.5Vdc and ≤10Vdc. The tip of the phone jack is positive (+) and the ring is
negative (-).

LED STATUS INDICATORS

CLIPPING: T his LED (light emitting diode) will flash RED when the output waveform is clipped indicating an
overload condition.
Lights RED to indicate the outputs are muted..
MUTE:
POWER:
GREEN indicates normal operation
RED indicates Standby
Blinking RED/GREEN a fault or thermal overload problem in the unit.
ANALOG4Aux2 / DIGITAL4Select:
I n B100-DA models: when this LED is illuminated green concurrently with either D1, D2, D3
or D4 LEDs, it indicates that the digital inputs D1 (SPDIF), D2 (SPDIF), D3 (TOSLINK) or D4
(TOSLINK) have been selected.
I n B100 & B100-P models: when illuminated green this LED indicates that the line level ana-
log audio input AUX-2 has been selected.
AUX1, CD, TUNER, TV/SAT VIDEO & RECORD:
One of these input source LEDs will light green to Indicate the active input. In digital mode
these LEDs will light RED if the bit stream is either absent or unacceptable.
When the left/right signal balance is being shifted one of these LEDs will light to indicate
BALANCE
which channel is being attenuated. Balance can be adjusted in 1dB increments to up to
-6dB in either direction. Stepping past -6dB in either direction will mute that channel fully
and the LED for that channel will turn red.
W hen both LEDs are on (red), PASS THROUGH mode is indicated. (See "Pass Through
Mode" on page 4)
Note: In some markets the LED indicators, which are normally red/green, may be red/blue instead. When
red/blue LEDs are supplied green is replaced with blue and orange is replaced with magenta in the
above descriptions.
REMOTE POWER CONTROL ~ 12 VOLT TRIGGER CONNECTOR
Two trigger outputs are provided. A 12Vdc signal is placed across the T1 and C pins of the 12V TRIGGERS con-
nector whenever the unit is fully powered up. Then the unit goes into standby this voltage is removed.
PROGRAMMING THE "T2" 12V TRIGGER OUTPUT
By default the T2 triggered output is inactive. To program this output to become active , whereupon a con-
trol voltage of 12Vdc will appear across T2 & C terminals whenever a specific source is selected, use the
handheld remote control as follows:
• Select the source that you want to coincide with T2 going active.
A 12Vdc signal will be placed across
the other pair of 12V TRIGGER output
pins (T2) whenever a certain user
programmed input is selected as the
source input (see below for program-
ming instructions). When any other
input source is selected the 12Vdc
control voltage will be removed from
these pins. Please note that C means
"common" here and both C pins are
electrically connected and identical.