Communicating, programmable thermostat
Table of Contents

Advertisement

Heat Controller, Inc.
NOTE: The thermostat must be confi gured for
programmable mode by installer to access the
Programmed Demand Reduction settings.
5.6.5.5.1 PROGRAMMED DEMAND
REDUCTION MODE
Through Programmed Demand Reduction
Mode, you can set the unit's limited operation
during the Programmed Demand Reduction
schedule.
Adjust the Programmed Demand Reduction
Mode settings using the up/down arrow buttons.
Press the center button to save changes.
DEMAND REDUCTION
PROGRAM OPERATION
NO DEMAND REDUCTION
NO AUXILIARY HEAT
NO 2ND STAGE COMP
SELECT OPTION
PREVIOUS
No Demand Reduction (default): During
the scheduled Programmed Demand
Reduction time (section 5.6.5.5.4), the
system operates normally based on the
setpoints.
No Auxiliary Heat: During the scheduled
Programmed Demand Reduction time
(section 5.6.5.5.4), auxiliary heat will not
be activated, regardless of the heating
demand.
No 2nd Stage Compressor: During the
scheduled Programmed Demand Reduction
time (section 5.6.5.5.4), the compressor is
limited to only part load (1st stage) operation
and auxiliary heat is turned off, regardless of
system demand.
NOTE 1: The thermostat must be confi gured for
auxiliary heat by installer to access the Demand
Reduction NO AUXILIARY HEAT option.
NOTE 2: The thermostat must be confi gured
for Multistage by installer to access the Demand
Reduction NO 2nd STAGE COMP option.
5.6.5.5.2 Whole House Dehumidifi cation -
PROGRAMMED DEMAND REDUCTION
This option allows for the customization
of Whole House Dehumidifi cation.
(Dehumidifi cation, optional) operation during the
Programmed Demand Reduction schedule.
7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT
OPTION FOR
SAVE
PROGRAMMED DEMAND
REDUCTION OPERATION
FOR CLIMADRY
WHEN DEMAND REDUCTION
SUSPEND CLIMADRY
ALLOW CLIMADRY
SELECT OPTION
PREVIOUS
Adjust the Programmed Demand Reduction
Whole House Dehumidifi cation settings using
the up/down arrow buttons. Press the center
button to save changes.
Suspend Whole House Dehumidifi cation
(default): During the scheduled
Programmed Demand Reduction
time (section 5.6.5.5.4), Whole House
Dehumidifi cation is turned off, regardless of
the dehumidifi cation demand.
Allow Whole House Dehumidifi cation:
During the scheduled Programmed Demand
Reduction time (section 5.6.5.5.4), Whole
House Dehumidifi cation will operate
normally.
NOTE: The thermostat must be confi gured
for humidity control by installer and the
DXM2 must be confi gured for Whole House
Dehumidifi cation operation to access Demand
Reduction Whole House Dehumidifi cation
settings.
5.6.5.5.3 FAN - PROGRAMMED DEMAND
REDUCTION
This option allows for the customization of
fan settings during the Programmed Demand
Reduction schedule.
PROGRAMMED DEMAND
REDUCTION FAN
WHEN DEMAND REDUCTION
AUTO FAN ONLY
ALLOW CONSTANT FAN
SELECT OPTION
PREVIOUS
Adjust the Programmed Demand Reduction
Fan settings using the up/down arrow buttons.
Press the center button to save changes.
11
IS ACTIVE
SAVE
OPERATION
IS ACTIVE
SAVE