Installing Drain Line and P-Trap

DRAIN
PAN
HR
BOTTOM
NUT
Fig. 8.
Installing drain line.
TAPE
TO DRAIN
Fig. 9.
Installing P-trap.
HR150, 200; ER150, 200 Perfect Window™ Fresh Air Ventilation Systems 68-0171—12
There are two holes at the bottom of the ventilator for
the drain pan connectors.
O RING
1.
Insert the connectors through the hole in the drain pan
and the bottom of the unit.
2.
Place the washer and nut on the connector.
3.
Hand tighten the nut. See Fig. 8.
WASHER
M6552
Construct a P-trap using the plastic T-fitting provided.
1.
Cut two lengths of 1/2 in. ID hose and connect each
drain fitting to the end of the T-fitting.
2.
Position the center leg of the T-fitting so it points upward.
3.
Connect the drain line to the center leg and tape it in
place to prevent any kinks. See Fig. 9.
T FITTING
M6551
This creates a trap that will hold some condensation
and prevent odors from being drawn up through the
drain hose into the unit. If the unit is installed during a
season when it is unlikely that condensation will form,
fill the trap with tap water.
11