Other Features; Control Pads On The Dehumidifier - Heat Controller R-410A Owner's Manual

Bhd-h series portable dehumidifier
Table of Contents

Advertisement

Service Questions: Contact Comfort Aire at (517) 787-2100
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com
Owner's Manual
e
10
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(¡5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
ht

Other features

Bucket Full Light
Illuminates when the bucket is ready to be
emptied, or when the bucket is removed
or not seated in the proper position.
Auto Shut Off
The
dehumidifier
the bucket is full, or when the bucket is removed
or not seated in the proper position. When the
set humidity is reached, the unit will shut off
automatically. For some models, the fan motor
will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restarted
of
in the first 3 minutes. This is to protect the unit.
ve
Operation will automatically occur after
3 minutes.
ower
Check filter feature
higher
The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light(Clean filter indicator light) flashes one time
per second. After cleaning the air filter, press the
Filter pad to turn the filter light (clean filter indicator
ature,
light) off the time resets.
BHD-H Portable Dehumidifier

CONTROL PADS ON THE DEHUMIDIFIER

shuts off after 30 seconds when
EC- Unit malfunction--Ensure the unit is operating within
the design parameters for temperature. If this error occurs,
turn off the unit and turn on again to reset. If this error
occurs after powering off and back on call for service.
Auto-Restart
If the unit turns off unexpectedly due to power outage,
it will restart with the previous function setting automa-
tically when the power resumes.
Setting the Timer
When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.