Fireplace Insert Installation
Insert with Face
Seal Connection
NOTE:
Face seal connections
require installation of the
surround panels and
insulation (see the
"Surround Panel
Installation" on page
44).
© Travis Industries
NOTE: This installation may be
used with a masonry fireplace
only. The requirements in the
section "Masonry Fireplace
Requirements" must be fulfilled
prior to installation.
Flue
Liner
Combustible Mantle
Surround Panels with
insulation (see "Surround
Panels" installation
instructions in the back of
the manual)
See the section "Insert
Placement Requirements"
for minimum clearances
and hearth required.
(for qualified installers only)
93508061
NOTE: It is
recommended your
chimney have a
minimum 28 and a
maximum of 144
square inch cross-
sectional area to use a
face seal connection,
otherwise your
chimney maynot have
sufficient draw for the
fireplace insert to
operate correctly.
Airtight Insulated
Clean-Out
Remove damper
or wire it open
4050526